S25.10 General Cabin Arrangement
ED
Decision 2017/015/R
(a) Interior Doors on Non-Commercially
Operated Aeroplanes (See AMC to Appendix S, S25.10(a)): For a non-commercially operated
aeroplane, installation of doors that results in non-compliance with CS 25.813(e)
is acceptable provided that it is ensured by design and procedure that:
(1) each door is open before entering any of
the taxiing, take-off, and landing phases;
(2) each door remains open during taxiing,
take-off, and landing, and especially during and after a crash landing; and
(3) in the case of any probable failure or
jamming of a door in a position other than fully open, any occupant is able,
from any compartment separated by that door, to restore in an easy and simple
manner a sufficient opening to access the compartment on the other side of the
door.
(b) Interior Doors on Commercially Operated
Aeroplanes (See AMC to Appendix S, S25.10(b)): For a low-occupancy aeroplane
having a passenger seating configuration of 19 or less, installation of doors
that results in non-compliance with CS 25.813(e) is acceptable provided that the
conditions of S25.10(a)(1), S25.10(a)(2) and S25.10(a)(3) are complied with
and the following additional requirements are met for each passenger
compartment created by a door or doors:
(1) Within the compartment, there is at least
one emergency exit above the waterline on each side of the fuselage that meets
at least the requirements of a type IV emergency exit for a compartment that
has a passenger seating configuration of nine seats or less, or of a type III
emergency exit otherwise; or
(2) Within the compartment, there is at least
one emergency exit above the waterline on one side of the fuselage that meets
at least the requirements of a type IV emergency exit for a compartment that
has a passenger seating configuration of nine seats or less, or of a type III
emergency exit otherwise, and:
(i) an occupant of the compartment would not
need to go through more than one door to access an emergency exit above the
waterline on the other side of the fuselage; and
(ii) the demonstration of compliance with the
provisions S25.10(a)(1) and (2) does not rely on any passenger action, nor
involve any flight crew member leaving their position in the cockpit.
(c) Isolated Compartments: each cabin
compartment isolated from the rest of the cabin such that a fire starting in
the compartment would not be directly and quickly detected by the occupants of
another compartment, in an aeroplane that has a passenger seating
configuration of 20 or more, or which has a cabin length of more than 18.29 m
(60 ft), must be equipped with a smoke/fire detection system or equivalent
which allows detection within one minute after the start of a fire and
provides a visual indication in the cockpit, or a visual indication or audible
warning in the passenger cabin that would be readily detected by a cabin crew
member. However, if it can be demonstrated that a fire would be directly and
quickly detected because the compartment is likely to be occupied for the
majority of the flight time, such a system is not required (See AMC to Appendix S, S25.10(c)).
(d) Deactivation of existing Emergency Exits:
Deactivation of one of more emergency exits that results in non-compliance
with CS 25.807(e) is acceptable, provided that compliance with
the following requirements is shown (See AMC to Appendix S, S25.10(d) and (e)):
(1) the number of passenger seats allowed in a
zone between two remaining adjacent pairs of emergency exits is limited to one
half of the combined rated capacity of the two pairs of emergency exits
(rounded to the nearest whole number);
(2) the number of passenger seats allowed in a
zone with only one remaining pair of emergency exits at one end (a so called
dead end zone) is limited to one half of the rated capacity of the pair of
emergency exits (rounded to the nearest whole number); and
(3) the distance from each passenger seat to
at least one remaining emergency exit, on each side of the fuselage, remains
compatible with easy egress from the aeroplane.
(e) Distance between Emergency Exits:
deactivation of emergency exits which results in non-compliance with CS
25.807(f)(4) is acceptable on non-commercially operated aeroplanes only,
provided that:
(1) compliance with S25.10(d) is shown; and
(2) a distance of more than 18.29 m (60 ft)
between adjacent remaining emergency exits is created only once per side of
the fuselage on each deck (See AMC to Appendix S, S25.10(d) and
(e)).
[Amdt
25/19]
EASA aviation regulations for large aeroplanes address cabin arrangements, specifically interior doors and emergency exits. Non-commercial planes can have doors violating safety standards if open during critical flight phases. Commercial planes with few seats need compliant emergency exits. Isolated compartments require fire detection. Deactivated exits necessitate reduced seating near remaining exits.
* Summary by Aviation.Bot - Always consult the original document for the most accurate information.
Loading collections...