Navigate / EASA

ETSO-C95a

ED Decision 2012/009/R

Mach Meters

1 Applicability

This ETSO gives the requirements which mach meters that are manufactured on or after the date of this ETSO must meet in order to be identified with the applicable ETSO marking.

2 Procedures

2.1 General

Applicable procedures are detailed in CS-ETSO Subpart A.

2.2 Specific

None.

3 Technical Conditions

3.1 Basic

3.1.1 Minimum Performance Standard

Standards set forth in the Society of Automotive Engineers Inc, (SAE) Aerospace Standard (AS) 8018A „Mach Meters“, dated 01/09/1996.

3.1.2 Environmental Standard

See CS-ETSO Subpart A paragraph 2.1

3.1.3 Computer Software

See CS-ETSO Subpart A paragraph 2.2

3.1.4 Electronic Hardware Qualification

See CS-ETSO Subpart A paragraph 2.3.

3.2 Specific

3.2.1 Failure Condition Classification

See CS-ETSO Subpart A paragraph 2.4.

Failure of the function defined in paragraph 3.1.1 of this ETSO has been determined to be a major failure condition.

4 Marking

4.1 General

Marking is detailed in CS-ETSO Subpart A paragraph 1.2.

4.2 Specific

None, marking in accordance with AS 8018A addendum 1 section 2 is optional.

5 Availability of Referenced Document

See CS-ETSO Subpart A paragraph 3.

[Amdt ETSO/7]