#### ETSO-C95a *ED Decision 2012/009/R* ##### **Mach Meters** **1 Applicability** This ETSO gives the requirements which mach meters that are manufactured on or after the date of this ETSO must meet in order to be identified with the applicable ETSO marking. **2 Procedures** 2.1 General Applicable procedures are detailed in CS-ETSO [Subpart A](#_DxCrossRefBm920220672). 2.2 Specific None. **3 Technical Conditions** 3.1 Basic 3.1.1 Minimum Performance Standard Standards set forth in the Society of Automotive Engineers Inc, (SAE) Aerospace Standard (AS) 8018A „Mach Meters“, dated 01/09/1996. 3.1.2 Environmental Standard See CS-ETSO Subpart A paragraph 2.1 3.1.3 Computer Software See CS-ETSO Subpart A paragraph 2.2 3.1.4 Electronic Hardware Qualification See CS-ETSO Subpart A paragraph 2.3. 3.2 Specific 3.2.1 Failure Condition Classification See CS-ETSO Subpart A paragraph 2.4. Failure of the function defined in paragraph 3.1.1 of this ETSO has been determined to be a major failure condition. **4 Marking** 4.1 General Marking is detailed in CS-ETSO Subpart A paragraph 1.2. 4.2 Specific None, marking in accordance with AS 8018A addendum 1 section 2 is optional. **5 Availability of Referenced Document** See CS-ETSO Subpart A paragraph 3. [Amdt ETSO/7]