ED Decision 2005/006/R
(a) APU
mounted accessories must be approved for installation on the APU concerned and
use the provisions of the APU for mounting.
(b) Electrical
equipment subject to arcing or sparking must be installed to minimise the
probability of contact with any flammable fluids or vapours that might be
present in a free state.
(c) For
essential APUs:
If continued rotation of a failed aeroplane accessory driven by the APU
affects the safe operation of the aeroplane, there must be means to prevent
rotation without interfering with the continued operation of the APU.
[Amdt 25/1]