(a) Means
must be provided on the flight deck for starting, stopping, and emergency shutdown
of each installed APU. Each control must:
(1) Be located, arranged, and designed under CS 25.777(a)(b)(c)(d) and
marked under CS 25.1555(a); and
(2) Be located so that it cannot be
inadvertently operated by persons entering, leaving, or moving normally on the
flight deck; and
(3) Be able to maintain any set position
without constant attention by flight crew members and without creep due to
control loads or vibration; and
(4) Have sufficient strength and rigidity to
withstand operating loads without failure and without excessive deflection;
and
(5) For flexible controls, be approved or must
be shown to be suitable for the particular application.
(b) APU
valve controls located in the flight deck must have:
(1) For manual valves, positive stops or, in
the case of fuel valves, suitable index provisions in the open and closed
positions,
(2) In the case of valves controlled from the
flight deck other than by mechanical means, where the correct functioning of
the valve is essential for the safe operation of the aeroplane, a valve
position indicator which senses directly that the valve has attained the
position selected must be provided, unless other indications in the flight
deck give the flight crew a clear indication that the valve has moved to the
selected position. A continuous
indicator need not be provided.
(c) For
unattended operation, the APU installation must:
(1) Provide means to automatically shutdown
the APU for the following conditions:
(i) Exceedence
of any APU parameter limit or existence of a detectable hazardous APU
operating condition; and
(ii) Bleed
air duct failure between the APU and aeroplane unit served by the bleed air,
unless it can be shown that no hazard exists to the aeroplane.
(2) Provide means to automatically shut off
flammable fluids per CS
25J1189 in case of fire in the APU compartment.
(d) APU
controls located elsewhere on the aeroplane, which are in addition to the
flight deck controls, must meet the following requirements:
(1) Each control must be located so that it
cannot be inadvertently operated by persons entering, leaving, or moving
normally in the area of the control; and
(2) Each control must be able to maintain any
set position without creep due to control loads, vibration, or other external
forces resulting from the location.
(e) The
portion of each APU control located in a designated fire zone that is required
to be operated in the event of a fire must be at least fire resistant.
[Amdt 25/1]
EASA regulations mandate specific flight deck controls for aircraft Auxiliary Power Units (APUs), including start, stop, and emergency shutdown. These controls must be accessible, prevent inadvertent operation, and maintain set positions. APUs must automatically shut down upon exceeding limits, hazardous conditions, or fire. Valve controls require position indicators.