CS 25.973 Fuel tank filler connection
ED Decision 2003/2/RM
Each fuel tank filler connection must prevent the entrance of fuel into any part of the aeroplane other than the tank itself. In addition –
(a) Reserved
(b) Each recessed filler connection that can retain any appreciable quantity of fuel must have a drain that discharges clear of each part of the aeroplane;
(c) Each filler cap must provide a fuel-tight seal; and
(d) Each fuel filling point must have a provision for electrically bonding the aeroplane to ground fuelling equipment.