Navigate / EASA

CS 25.623 Bearing factors

ED Decision 2003/2/RM

(a)     Except as provided in sub-paragraph (b) of this paragraph, each part that has clearance (free fit), and that is subject to pounding or vibration, must have a bearing factor large enough to provide for the effects of normal relative motion.

(b)     No bearing factor need be used for a part for which any larger special factor is prescribed.