(a)     Oxygen equipment must be approved.

(b)     Oxygen equipment must be free from hazards in itself, in its method of operation, and its effect upon other components.

(c)      There must be a means to allow the crew to readily determine, during the flight, the quantity of oxygen available in each source of supply.

(d)     Oxygen bottles must be installed so as not to be hazardous in crash landings.