Navigate / EASA
Appendix 2 to ETSO-2C48a – Additional Tests

ED Decision 2010/010/R

The following additional tests are required.

a Effect of Fuel contaminated air.

i Air contaminated with 1,000 ppm by volume of 100LL fuel is to be passed through the instrument for 2 hours

ii Verify that there are no false alarms during that period

iii Pass test sample D through the instrument and ensure that the alarm is triggered between 10 and 40 minutes

iv Repeat 2.2-a, 2.2-b and 2.2-c using JET A1 fuel.

v Repeat 2.2-a, 2.2-b and 2.2-c using MOGAS Leaded fuel to BS:4040:1988.

vi Repeat 2.2-a, 2.2-b and 2.2-c using MOGAS Unleaded fuel to BS:7070 or EN228:1995.

vii Repeat 2.2-a, 2.2-b and 2.2-c using diesel fuel

[Amdt ETSO/6]