ED Decision 2020/011/R
The applicable standard is SAE AS245B, Water Solution Type Hand Fire Extinguisher, dated (revised) April 2004, shall be modified as follows:
AS245B section |
Action |
||||||||
Paragraph 4.1.2: Burst pressure |
to be revised as follows: The burst pressure must be greater than or equal to ‘b’ times the design pressure (see Table 1 below). The design pressure is compatible with the maximum pressure encountered in use of the extinguisher and ensures a long service life for equipment when charged. |
||||||||
Paragraph 5. Individual Performance Requirements: |
to be revised as follows: All extinguishers, or extinguisher components shall be subjected at a minimum to the following tests: |
||||||||
Requirement to be added: the proof pressure must be greater than or equal to ‘p’ times the design pressure (see table 1 below). Table 1: the ‘b’ and ‘p’ factors indicated depend on the type of extinguisher
|
[Amdt ETSO/12]
[Amdt ETSO/16]