Appendix 1 to ETSO-2C19c A1 – MPS Portable Water Solution Type Hand Fire Extinguishers

ED Decision 2020/011/R

The applicable standard is SAE AS245B, Water Solution Type Hand Fire Extinguisher, dated (revised) April 2004, shall be modified as follows:



AS245B section

Action

Paragraph 4.1.2: Burst pressure

to be revised as follows:

The burst pressure must be greater than or equal to ‘b’ times the design pressure (see Table 1 below). The design pressure is compatible with the maximum pressure encountered in use of the extinguisher and ensures a long service life for equipment when charged.

Paragraph 5. Individual Performance

Requirements:

to be revised as follows:

All extinguishers, or extinguisher components shall be subjected at a minimum to the following tests:

Requirement to be added:

the proof pressure must be greater than or equal to ‘p’ times the design pressure (see table 1 below).

Table 1:

the ‘b’ and ‘p’ factors indicated depend on the type of extinguisher



b

p

Type I

2,7

1,5

Type II

2,4

1,2




[Amdt ETSO/12]

[Amdt ETSO/16]