Navigate / EASA

ETSO-C89a

ED Decision 2016/013/R

Crew Member Oxygen Regulator, Demand

1 Applicability

This ETSO provides the requirements which Crew Member Oxygen Regulator, Demand that are designed and manufactured on or after the date of this ETSO must meet in order to be identified with the applicable ETSO marking.

2 Procedures

2.1 General

Applicable procedures are detailed in CS-ETSO, Subpart A.

2.2 Specific

None.

3 Technical Conditions

3.1 Basic

3.1.1 Minimum Performance Standard

Standards set forth in the SAE AS8027, Crew Member Oxygen Regulator, Demand, dated 1 June2004, as modified by Appendix 1 to this ETSO.

Crew member oxygen regulators are separated into four types:

Type I: Remote-mounted, panel or portable,

Type II: Man-mounted, not mask-mounted,

Type III: Mask-mounted, less valving, and

Type IV: Mask-mounted, with integral valving.



The four types of oxygen regulators are further separated into five classes:

Class A: Straight demand,

Class B: Diluter demand,

Class C: Straight demand, pressure breathing,

Class D: Diluter demand, pressure breathing to 40 000 ft, and

Class E: Diluter demand, pressure breathing to 45 000 ft.

3.1.2 Environmental Standard

Refer to SAE AS8027, paragraph 4.5

3.1.3 Computer Software

None.

3.1.4 Electronic Hardware Qualification

None.

3.2 Specific

None.

3.2.1 Failure Condition Classification

See CS-ETSO, Subpart A, paragraph 2.4.

4 Marking

4.1 General

Marking is detailed in CS-ETSO, Subpart A, paragraph 1.2.

4.2 Specific

Type and class (refer to paragraph 3),

Maximum altitude (per AS8027, paragraph 1.2.3),

Inlet supply pressure range (per AS8027, paragraph 3.1.7).

5 Availability of Referenced Document

See CS-ETSO, Subpart A, paragraph 3.

[Amdt ETSO/11]