ED Decision 2020/011/R
This Appendix defines the modifications and additions to the MPS for pressure altimeter equipment specified in SAE AS8009C, Pressure Altimeter Systems, dated 24 May 2016.
SAE AS8009C Section(s) |
Change |
3.4 |
Add a note following the paragraph to read: Note: Markings for the altitude range may be omitted for instruments that use a tape-type display. |
3.10 |
Delete current Section 3.10 and Table 9. Replace with the following: 3.10 Temperature Corrections Altimeters covered by this standard shall not incorporate automatic temperature corrections. |
3.11 |
Add a new third paragraph to read: Instruments that use a tape-type display or present altitude with a digital readout are permitted to use tic marks every 100 feet with a more prominent mark every 500 feet in agreement with SAE ARP4102/7, Appendix A, Symbols 39 and/or 40. |
3.12 |
Change the third sentence to read: The word ALTITUDE or ALT may be marked on the dial in capital letters and may be in the same finish as the numerals. |
3.12 |
Add a note following the paragraph to read: Note: Markings for the altitude range may be omitted for instruments that use a tape‑type display. |
5. |
Add a new paragraph: Some of these tests may be performed only once provided that it is demonstrated that this test will demonstrate performance for each article. |
5.10 |
Add a new paragraph: For altimeters with an electronic display, this test may be replaced by showing compliance with SAE AS8034C, Section 3.8, Malfunctions/Failure Indications and Section 4.6, Operating Time. |
5.11 |
Add a requirement for performance testing of Electronic Display Altimeters: Electronic displays shall demonstrate their compliance with the SAE AS8034C requirements specified in Table 10 using the test procedures specified in SAE AS8034C, Section 6, as applicable. |
6.29 |
Add a requirement for environmental testing of Electronic Display Altimeters: Electronic displays shall demonstrate the compliance of their equipment with the requirements of SAE AS8034B specified in Table 10 using the environmental performance requirements specified in SAE AS8034B, Section 5. |
ETSO-C10c Appendix 1 modifies SAE AS8009C for pressure altimeter systems, adding display-specific marking rules, prohibiting automatic temperature corrections, and imposing SAE AS8034C/B performance and environmental con
* Summary by Aviation.Bot - Always consult the original document for the most accurate information.