CS 27.1395 Maximum
intensities in overlapping beams of forward and rear position lights
ED Decision 2003/15/RM
No position light intensity may exceed the applicable values in the following table, except as provided in CS 27.1389(b)(3):
|
Overlaps |
Maximum
intensity |
|
|
Area A (candelas) |
Area B (candelas) |
|
|
Green in dihedral angle L |
10 |
1 |
|
Red in dihedral angle R |
10 |
1 |
|
Green in dihedral angle A |
5 |
1 |
|
Red in dihedral angle A |
5 |
1 |
|
Rear white in dihedral angle L |
5 |
1 |
|
Rear white in dihedral angle R |
5 |
1 |
Where:
(a) Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10° but less than 20°; and
(b) Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20°.