CS 25J1203 Fire-detector system
ED Decision 2005/006/R
(a) There
must be approved, quick acting fire or overheat detectors in each APU
compartment in numbers and locations ensuring prompt detection of fire.
(b) Each
fire detector system must be constructed and installed so that:
(1) It will withstand the vibration, inertia,
and other loads to which it may be subjected in operation;
(2) There is a means to warn the crew in the
event that the sensor or associated wiring within a designated fire zone is
severed at one point, unless the system continues to function as a
satisfactory detection system after the severing; and
(3) There is a means to warn the crew in the
event of a short circuit in the sensor or associated wiring within a
designated fire zone, unless the system continues to function as a
satisfactory detection system after the short circuit.
(c) No
fire or overheat detector may be affected by any oil, water, other fluids, or
fumes that might be present.
(d) There
must be means to allow the crew to check, in flight, the functioning of each
fire or overheat detector electric circuit.
(e) Wiring
and other components of each fire or overheat detector system in a fire zone
must be at least fire-resistant.
(f) No
fire or overheat detector system component for any fire zone may pass through
another fire zone, unless:
(1) It is protected against the possibility of
false warnings resulting from fires in zones through which it passes; or
(2) Each zone involved is simultaneously
protected by the same detector and extinguishing system.
(g) Each
fire detector system must be constructed so that when it is in the
configuration for installation it will not exceed the alarm activation time
approved for the detectors using the response time criteria specified in
ETSO-2C11e or an acceptable equivalent, for the detector.
[Amdt 25/1]