CS 25.1391 Minimum intensities in the horizontal plane of forward
and rear position lights
ED Decision 2003/2/RM
Each position light intensity must equal or exceed the applicable values in the following table:
Dihedral angle (light
included) |
Angle from
right or left of longitudinal axis, measured from dead ahead |
Intensity
candela (candles) |
L and R (forward red and green) A (rear white) |
0o to 10 o 10 o to 20 o 20 o to 110 o 110 o to 180 o |
41 (40) 31 (30) 5 20 |