Navigate / EASA

CS 25.1391 Minimum intensities in the horizontal plane of forward and rear position lights

ED Decision 2003/2/RM

Each position light intensity must equal or exceed the applicable values in the following table:

Dihedral angle

(light included)

Angle from right or left of longitudinal axis, measured from dead ahead

Intensity candela (candles)

L and R

(forward red and green)

 

A (rear white)

 0o to 10 o

 10 o to 20 o

 20 o to 110 o

110 o to 180 o

41 (40)

31 (30)

 5

20