CS 25.1395 Maximum intensities in over-lapping beams of forward and
rear position lights
ED Decision 2003/2/RM
No position light intensity may exceed the applicable values in the following table, except as provided in CS 25.1389(b)(3):
Overlaps |
Maximum
intensity |
|
Area A candela
(candles) |
Area B candela
(candles) |
|
Green in dihedral angle L |
10 |
1 |
Red in dihedral angle R |
10 |
1 |
Green in dihedral angle A |
5 |
1 |
Red in dihedral angle A |
5 |
1 |
Rear white in dihedral angle L |
5 |
1 |
Rear white in dihedral angle R |
5 |
1 |
Where –
(a) Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10° but less than 20°; and
(b) Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20°.