CS 25.1731 Powerplant and APU fire detector system; EWIS

ED Decision 2008/006/R

(a)     EWIS that are part of each fire or overheat detector system in a fire zone must be at least fire-resistant.

(b)     No EWIS component of any fire or overheat detector system for any fire zone may pass through another fire zone, unless:

(1)     It is protected against the possibility of false warnings resulting from fires in zones through which it passes; or

(2)     Each zone involved is simultaneously protected by the same detector and extinguishing system.

[Amdt 25/5]