Navigate / EASA

CS 25.954 Fuel system lightning protection

ED Decision 2020/024/R

(See AMC 25.954)

(a)     For the purposes of this paragraph—

(1)     A critical lightning strike is a lightning strike that attaches to the aeroplane in a location that, when combined with the failure of any design feature or structure, could create an ignition source.

(2)     A fuel system includes any component within either the fuel tank structure or the fuel tank systems, and any aeroplane structure or system components that penetrate, connect to, or are located within a fuel tank.

(b)     The design and installation of a fuel system must prevent catastrophic fuel vapour ignition due to lightning and its effects, including:

(1)     Direct lightning strikes to areas having a high probability of stroke attachment;

(2)     Swept lightning strokes to areas where swept strokes are highly probable; and

(3)     Lightning-induced or conducted electrical transients.

(c)      To comply with subparagraph (b) of this paragraph, catastrophic fuel vapour ignition must be extremely improbable, taking into account the flammability, critical lightning strikes, and failures within the fuel system.

(d)     To protect design features that prevent catastrophic fuel vapour ignition caused by lightning, the type design must include critical design configuration control limitations (CDCCLs) identifying those features and providing information to protect them. To ensure the continued effectiveness of those design features, the type design must also include inspection and test procedures, intervals between repetitive inspections and tests, and mandatory replacement times for those design features used in demonstrating compliance with subparagraph (b) of this paragraph. The applicant must include the information required by this subparagraph in the Airworthiness Limitations Section of the Instructions for Continued Airworthiness required by CS 25.1529.

[Amdt 25/18]

[Amdt 25/26]