AMC1 ORA.FSTD.115 Installations
ED
Decision 2012/007/R
MINIMUM
ELEMENTS FOR SAFE OPERATION
(a) Introduction
(1) This AMC identifies those elements that
are expected to be addressed, as a minimum, to ensure that the FSTD
installation provides a safe environment for the users and operators of the
FSTD under all circumstances.
(b) Expected elements
(1) Adequate fire/smoke detection, warning and
suppression arrangements should be provided to ensure safe passage of
personnel from the FSTD.
(2) Adequate protection should be provided
against electrical, mechanical, hydraulic and pneumatic hazards, including
those arising from the control loading and motion systems, to ensure maximum
safety of all persons in the vicinity of the FSTD.
(3) Other areas that should be addressed
include the following:
(i) a two-way communication system that
remains operational in the event of a total power failure;
(ii) emergency lighting;
(iii) escape exits and escape routes;
(iv) occupant restraints (seats, seat belts
etc.);
(v) external warning of motion and access
ramp or stairs activity;
(vi) danger area markings;
(vii) guard rails and gates;
(viii) motion and control loading emergency stop
controls accessible from either pilot or instructor seats;
(ix) a manual or automatic electrical power
isolation switch.