CS 25.1731 Powerplant and APU fire detector system
Available versions for ERULES-1963177438-9564
ED Decision 2008/006/R
found in: CS-25 Amdt 27 - Large Aeroplanes (Jan 2023)
Version
...23)
Text
Removed: 0
Added: 0
Unchanged: 0
Share
CS 25.1731 Powerplant and APU fire detector system; EWIS ED Decision 2008/006/R (a) EWIS that are part of each fire or overheat detector system in a fire zone must be at least fire-resistant. (b) No EWIS component of any fire or overheat detector system for any fire zone may pass through another fire zone, unless: (1) It is protected against the possibility of false warnings resulting from fires in zones through which it passes; or (2) Each zone involved is simultaneously protected by the same detector and extinguishing system. [Amdt 25/5]