Version
CS 25A1017 Oil lines and fittings ED Decision 2005/006/R (a) Each oil line must meet the requirements of [CS 25J993](#_DxCrossRefBm1709821900) and each oil line and fitting in any designated fire zone must meet the requirements of [CS 25J1183](#_DxCrossRefBm1709821906). (b) Breather lines must be arranged so that: (1) Condensed water vapour that might freeze and obstruct the line cannot accumulate at any point; (2) The breather discharge does not constitute a fire hazard; (3) The breather does not discharge into the APU air intake system. [Amdt 25/1]