###### Appendix 2 to ETSO-2C48a – Additional Tests *ED Decision 2010/010/R* The following additional tests are required. a Effect of Fuel contaminated air. i Air contaminated with 1,000 ppm by volume of 100LL fuel is to be passed through the instrument for 2 hours ii Verify that there are no false alarms during that period iii Pass test sample D through the instrument and ensure that the alarm is triggered between 10 and 40 minutes iv Repeat 2.2-a, 2.2-b and 2.2-c using JET A1 fuel. v Repeat 2.2-a, 2.2-b and 2.2-c using MOGAS Leaded fuel to BS:4040:1988. vi Repeat 2.2-a, 2.2-b and 2.2-c using MOGAS Unleaded fuel to BS:7070 or EN228:1995. vii Repeat 2.2-a, 2.2-b and 2.2-c using diesel fuel [Amdt ETSO/6]