CS-E 135 Electrical Bonding
Available versions for ERULES-1963177438-8860
ED Decision 2007/015/R
found in: CS-E Amdt 5 - Engines (Dec 2018)
Version
...18)
Text
Removed: 0
Added: 0
Unchanged: 0
Share
CS-E 135 Electrical Bonding ED Decision 2007/015/R (See [AMC E 135](#_DxCrossRefBm1371447666)) Any components, modules, equipment and accessories that are susceptible to or are potential sources of static discharges or currents from electrical Faults, must be designed and constructed so as to be grounded to the main Engine earth, as necessary to minimise the accumulation of electro-static or electrical charge that would cause: — Injury from electrical shock, — Unintentional ignition in areas where flammable fluids or vapours could be present, — Unacceptable interference with electrical or electronic equipment. [Amdt. No.: E/1]