AMC 25.1310(a) Power source capacity and distribution
Available versions for ERULES-1963177438-8755
ED Decision 2003/2/RM
found in: CS-25 Amdt 27 - Large Aeroplanes (Jan 2023)
Version
CS-25 Amdt 27 - La... (Jan 2023)
Section
Share
Version
Show details
Hide details
Version
AMC 25.1310(a) Power source capacity and distribution ED Decision 2003/2/RM When alternative or multiplication of systems and equipment is provided to meet the requirements of [CS 25.1310(a)](#_DxCrossRefBm1709821602), the segregation between circuits should be such as to minimise the risk of a single occurrence causing multiple failures of circuits or power supplies of the system concerned. For example, electrical cable bundles or groups of hydraulic pipes should be so segregated as to prevent damage to the main and alternative systems and power supplies.