CS 25.689 Cable systems
Available versions for ERULES-1963177438-8651
ED Decision 2003/2/RM
found in: CS-25 Amdt 27 - Large Aeroplanes (Jan 2023)
Version
CS-25 Amdt 27 - La... (Jan 2023)
Section
Share
Version
Show details
Hide details
Version
CS 25.689 Cable systems ED Decision 2003/2/RM (a) Each cable, cable fitting, turnbuckle, splice, and pulley must be approved. In addition – (1) No cable smaller than 3.2 mm (0·125 inch) diameter may be used in the aileron, elevator, or rudder systems; and (2) Each cable system must be designed so that there will be no hazardous change in cable tension throughout the range of travel under operating conditions and temperature variations. (b) Each kind and size of pulley must correspond to the cable with which it is used. Pulleys and sprockets must have closely fitted guards to prevent the cables and chains from being displaced or fouled. Each pulley must lie in the plane passing through the cable so that the cable does not rub against the pulley flange. (c) Fairleads must be installed so that they do not cause a change in cable direction of more than three degrees. (d) Clevis pins subject to load or motion and retained only by cotter pins may not be used in the control system. (e) Turnbuckles must be attached to parts having angular motion in a manner that will positively prevent binding throughout the range of travel. (f) There must be provisions for visual inspection of fairleads, pulleys, terminals, and turnbuckles.