CS 25.1015 Oil tank tests
Available versions for ERULES-1963177438-8442
ED Decision 2003/2/RM
found in: CS-25 Amdt 27 - Large Aeroplanes (Jan 2023)
Version
CS-25 Amdt 27 - La... (Jan 2023)
Section
Share
Version
Show details
Hide details
Version
CS 25.1015 Oil tank tests ED Decision 2003/2/RM Each oil tank must be designed and installed so that – (a) It can withstand, without failure, each vibration, inertia, and fluid load that it may be subjected to in operation; and (b) It meets the provisions of [CS 25.965](#_DxCrossRefBm1709821446), except – (1) The test pressure – (i) For pressurised tanks used with a turbine engine, may not be less than 34 kPa (5 psi) plus the maximum operating pressure of the tank instead of the pressure specified in [CS 25.965(a)](#_DxCrossRefBm1709821446); and (ii) For all other tanks, may not be less than 34 kPa (5 psi) instead of the pressure specified in [CS 25.965(a)](#_DxCrossRefBm1709821446); and (2) The test fluid must be oil at 121°C (250°F) instead of the fluid specified in [CS 25.965(c)](#_DxCrossRefBm1709821446).