Light
Dark
System
Log In
Loading...
Compare / EASA/
Incorporated Amendments
/
Compare & Highlight Differences
CS-VLA 857 Electrical bonding
Available versions for ERULES-1963177438-8042
ED Decision 2003/18/RM
found in: CS-VLA Amdt 1 - Very Light Aeroplanes (Mar 2009)
Version
CS-VLA Amdt 1 - Ve... (Mar 2009)
Section
Share
Version
Show details
Hide details
Version
CS-VLA 857 Electrical bonding ED Decision 2003/18/RM (a) Electrical continuity must be provided to prevent the existence of difference of potential between components of the powerplant including fuel and other tanks, and other significant parts of the aeroplane which are electrically conductive. (b) The cross-sectional areas of bonding connectors if made from copper must not be less than 1.3 mm\*. (c) There must be provisions for electrically bonding the aeroplane to the ground fuelling equipment.