CS-VLA 625 Fitting factors
Available versions for ERULES-1963177438-7844
ED Decision 2003/18/RM
found in: CS-VLA Amdt 1 - Very Light Aeroplanes (Mar 2009)
Version
CS-VLA Amdt 1 - Ve... (Mar 2009)
Section
Share
Version
Show details
Hide details
Version
CS-VLA 625 Fitting factors ED Decision 2003/18/RM For each fitting (a part or terminal used to joint one structural member to another), the following apply: (a) For each fitting whose strength is not proven by limit and ultimate load tests in which actual stress conditions are simulated in the fitting and surrounding structures, a fitting factor of at least 1.15 must be applied to each part of - (1) The fitting; (2) The means of attachment; and (3) The bearing on the joined members. (b) No fitting factor need be used for joint designs based on comprehensive test data (such as continuous joints in metal plating, welded joints, and scarf joints in wood). (c) For each integral fitting, the part must be treated as a fitting up to the point at which the section properties become typical of the member. (d) For each seat, and safety belt with harness, its attachment to the structure must be shown by analysis, tests, or both, to be able to withstand the inertia forces prescribed in [CS-VLA 561](#_DxCrossRefBm584936738) multiplied by a fitting factor of 1.33.