Light
Dark
System
Log In
Loading...
Compare / EASA/
Incorporated Amendments
/
Compare & Highlight Differences
CS 27.610 Lightning and static electricity protection
Available versions for ERULES-1963177438-6693
ED Decision 2016/024/R
found in: CS-27 Amdt 9 - Small Rotorcraft (Dec 2021)
From
CS-27 Amdt 10 - Sm... (Feb 2023)
CS-27 Amdt 9 - Sma... (Dec 2021)
From section
To
CS-27 Amdt 10 - Sm... (Feb 2023)
CS-27 Amdt 9 - Sma... (Dec 2021)
To section
No visible text changes
0 removals
0 additions
View
Rich
Plain
Sync scrolling
Share
From
Show details
Hide details
To
Show details
Hide details
Version
Show side by side
CS 27.610 Lightning and static electricity protection ED Decision 2016/024/R (a) The rotorcraft must be protected against catastrophic effects from lightning. (b) For metallic components, compliance with sub-paragraph (a) may be shown by: (1) Electrically bonding the components properly to the airframe; or (2) Designing the components so that a strike will not endanger the rotorcraft. (c) For non-metallic components, compliance with sub-paragraph (a) may be shown by: (1) Designing the components to minimise the effect of a strike; or (2) Incorporating acceptable means of diverting the resulting electrical current so as not to endanger the rotorcraft. (d) The electrical bonding and protection against lightning and static electricity must: (1) Minimise the accumulation of electrostatic charge; (2) Minimise the risk of electric shock to crew, passengers, and service and maintenance personnel using normal precautions; (3) Provide an electrical return path, under both normal and fault conditions, on rotorcraft having grounded electrical systems; and (4) Reduce to an acceptable level the effects of static electricity on the functioning of essential electrical and electronic equipment. [Amdt 27/4]
CS 27.610 Lightning and static electricity protection ED Decision 2016/024/R (a) The rotorcraft must be protected against catastrophic effects from lightning. (b) For metallic components, compliance with sub-paragraph (a) may be shown by: (1) Electrically bonding the components properly to the airframe; or (2) Designing the components so that a strike will not endanger the rotorcraft. (c) For non-metallic components, compliance with sub-paragraph (a) may be shown by: (1) Designing the components to minimise the effect of a strike; or (2) Incorporating acceptable means of diverting the resulting electrical current so as not to endanger the rotorcraft. (d) The electrical bonding and protection against lightning and static electricity must: (1) Minimise the accumulation of electrostatic charge; (2) Minimise the risk of electric shock to crew, passengers, and service and maintenance personnel using normal precautions; (3) Provide an electrical return path, under both normal and fault conditions, on rotorcraft having grounded electrical systems; and (4) Reduce to an acceptable level the effects of static electricity on the functioning of essential electrical and electronic equipment. [Amdt 27/4]