Light
Dark
System
Log In
Loading...
Compare / EASA/
Incorporated Amendments
/
Compare & Highlight Differences
CS 29.1521 Powerplant limitations
Available versions for ERULES-1963177438-5699
ED Decision 2003/16/RM
found in: CS-29 Amdt 10 - Large Rotercraft (Jan 2023)
From
CS-29 Amdt 12 - La... (Mar 2026)
CS-29 Amdt 11 - La... (Feb 2023)
CS-29 Amdt 10 - La... (Jan 2023)
From section
To
CS-29 Amdt 12 - La... (Mar 2026)
CS-29 Amdt 11 - La... (Feb 2023)
CS-29 Amdt 10 - La... (Jan 2023)
To section
No visible text changes
0 removals
0 additions
View
Rich
Plain
Sync scrolling
Share
From
Show details
Hide details
To
Show details
Hide details
Version
Show side by side
CS 29.1521 Powerplant limitations ED Decision 2003/16/RM (a) General. The powerplant limitations prescribed in this paragraph must be established so that they do not exceed the corresponding limits for which the engines are type certificated. (b) Take-off operation. The powerplant take- off operation must be limited by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor design; or (ii) The maximum value shown during the type tests; (2) The maximum allowable manifold pressure (for reciprocating engines); (3) The maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (4) The maximum allowable power or torque for each engine, considering the power input limitations of the transmission with all engines operating; (5) The maximum allowable power or torque for each engine considering the power input limitations of the transmission with one engine inoperative; (6) The time limit for the use of the power corresponding to the limitations established in sub-paragraphs (b)(1) to (5); and (7) If the time limit established in sub-paragraph (b)(6) exceeds 2 minutes: (i) The maximum allowable cylinder head or coolant outlet temperature (for reciprocating engines); and (ii) The maximum allowable engine and transmission oil temperatures. (c) Continuous operation. The continuous operation must be limited by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor design; or (ii) The maximum value shown during the type tests; (2) The minimum rotational speed shown under the rotor speed requirements in [CS 29.1509(c)](#_DxCrossRefBm1513259781); (3) The maximum allowable manifold pressure (for reciprocating engines); (4) The maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (5) The maximum allowable power or torque for each engine, considering the power input limitations of the transmission with all engines operating; (6) The maximum allowable power or torque for each engine, considering the power input limitations of the transmission with one engine inoperative; and (7) The maximum allowable temperatures for – (i) The cylinder head or coolant outlet (for reciprocating engines); (ii) The engine oil; and (iii) The transmission oil. (d) Fuel grade or designation. The minimum fuel grade (for reciprocating engines) or fuel designation (for turbine engines) must be established so that it is not less than that required for the operation of the engines within the limitations in sub-paragraphs (b) and (c). (e) Ambient temperature. Ambient temperature limitations (including limitations for winterization installations if applicable) must be established as the maximum ambient atmospheric temperature at which compliance with the cooling provisions of [CS 29.1041](#_DxCrossRefBm1513259634) to [29.1049](#_DxCrossRefBm1513259633) is shown. (f) Two and one-half minute OEI power operation. Unless otherwise authorised, the use of 2½-minute OEI power must be limited to engine failure operation of multi-engine, turbine powered rotorcraft for not longer than 2½ minutes for any period in which that power is used. The use of 2½-minute OEI power must also be limited by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor design; or (ii) The maximum value shown during the type tests; (2) The maximum allowable gas temperature; (3) The maximum allowable torque; and (4) The maximum allowable oil temperature. (g) Thirty-minute OEI power operation. Unless otherwise authorised, the use of 30-minute OEI power must be limited to multi-engine, turbine-powered rotorcraft for not longer than 30 minutes after failure of an engine. The use of 30-minute OEI power must also be limited by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor design; or (ii) The maximum value shown during the type tests; (2) The maximum allowable gas temperature; (3) The maximum allowable torque; and (4) The maximum allowable oil temperature. (h) Continuous OEI power operation. Unless otherwise authorised, the use of continuous OEI power must be limited to multi-engine, turbine- powered rotorcraft for continued flight after failure of an engine. The use of continuous OEI power must also be limited by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor design; or (ii) The maximum value shown during the type tests. (2) The maximum allowable gas temperature; (3) The maximum allowable torque; and (4) The maximum allowable oil temperature. (i) Rated 30-second OEI power operation. Rated 30-second OEI power is permitted only on multi-engine, turbine-powered rotorcraft also certificated for the use of rated 2-minute OEI power, and can only be used for continued operation of the remaining engine(s) after a failure or precautionary shutdown of an engine. It must be shown that following application of 30-second OEI power, any damage will be readily detectable by the applicable inspections and other related procedures furnished in accordance with paragraph A29.4 of [Appendix A](#_DxCrossRefBm1513259458) of CS-29. The use of 30-second OEI power must be limited to not more than 30 seconds for any period in which the power is used and by: (1) The maximum rotational speed which may not be greater than: (i) The maximum value determined by the rotor design: or (ii) The maximum value demonstrated during the type tests; (2) The maximum allowable gas temperature; and (3) The maximum allowable torque. (j) Rated 2-minute OEI power operation. Rated 2-minute OEI power is permitted only on multi-engine, turbine-powered rotorcraft, also certificated for the use of rated 30-second OEI power, and can only be used for continued operation of the remaining engine(s) after a failure or precautionary shutdown of an engine. It must be shown that following application of 2-minute OEI power, any damage will be readily detectable by the applicable inspections and other related procedures furnished in accordance with paragraph A29.4 of [Appendix A](#_DxCrossRefBm1513259458) of CS-29. The use of 2-minute OEI power must be limited to not more than 2 minutes for any period in which that power is used, and by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor designs; or (ii) The maximum value demonstrated during the type tests; (2) The maximum allowable gas temperature; and (3) The maximum allowable torque.
CS 29.1521 Powerplant limitations ED Decision 2003/16/RM (a) General. The powerplant limitations prescribed in this paragraph must be established so that they do not exceed the corresponding limits for which the engines are type certificated. (b) Take-off operation. The powerplant take- off operation must be limited by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor design; or (ii) The maximum value shown during the type tests; (2) The maximum allowable manifold pressure (for reciprocating engines); (3) The maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (4) The maximum allowable power or torque for each engine, considering the power input limitations of the transmission with all engines operating; (5) The maximum allowable power or torque for each engine considering the power input limitations of the transmission with one engine inoperative; (6) The time limit for the use of the power corresponding to the limitations established in sub-paragraphs (b)(1) to (5); and (7) If the time limit established in sub-paragraph (b)(6) exceeds 2 minutes: (i) The maximum allowable cylinder head or coolant outlet temperature (for reciprocating engines); and (ii) The maximum allowable engine and transmission oil temperatures. (c) Continuous operation. The continuous operation must be limited by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor design; or (ii) The maximum value shown during the type tests; (2) The minimum rotational speed shown under the rotor speed requirements in [CS 29.1509(c)](#_DxCrossRefBm1178332197); (3) The maximum allowable manifold pressure (for reciprocating engines); (4) The maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (5) The maximum allowable power or torque for each engine, considering the power input limitations of the transmission with all engines operating; (6) The maximum allowable power or torque for each engine, considering the power input limitations of the transmission with one engine inoperative; and (7) The maximum allowable temperatures for – (i) The cylinder head or coolant outlet (for reciprocating engines); (ii) The engine oil; and (iii) The transmission oil. (d) Fuel grade or designation. The minimum fuel grade (for reciprocating engines) or fuel designation (for turbine engines) must be established so that it is not less than that required for the operation of the engines within the limitations in sub-paragraphs (b) and (c). (e) Ambient temperature. Ambient temperature limitations (including limitations for winterization installations if applicable) must be established as the maximum ambient atmospheric temperature at which compliance with the cooling provisions of [CS 29.1041](#_DxCrossRefBm1178332041) to [29.1049](#_DxCrossRefBm1178332040) is shown. (f) Two and one-half minute OEI power operation. Unless otherwise authorised, the use of 2½-minute OEI power must be limited to engine failure operation of multi-engine, turbine powered rotorcraft for not longer than 2½ minutes for any period in which that power is used. The use of 2½-minute OEI power must also be limited by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor design; or (ii) The maximum value shown during the type tests; (2) The maximum allowable gas temperature; (3) The maximum allowable torque; and (4) The maximum allowable oil temperature. (g) Thirty-minute OEI power operation. Unless otherwise authorised, the use of 30-minute OEI power must be limited to multi-engine, turbine-powered rotorcraft for not longer than 30 minutes after failure of an engine. The use of 30-minute OEI power must also be limited by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor design; or (ii) The maximum value shown during the type tests; (2) The maximum allowable gas temperature; (3) The maximum allowable torque; and (4) The maximum allowable oil temperature. (h) Continuous OEI power operation. Unless otherwise authorised, the use of continuous OEI power must be limited to multi-engine, turbine- powered rotorcraft for continued flight after failure of an engine. The use of continuous OEI power must also be limited by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor design; or (ii) The maximum value shown during the type tests. (2) The maximum allowable gas temperature; (3) The maximum allowable torque; and (4) The maximum allowable oil temperature. (i) Rated 30-second OEI power operation. Rated 30-second OEI power is permitted only on multi-engine, turbine-powered rotorcraft also certificated for the use of rated 2-minute OEI power, and can only be used for continued operation of the remaining engine(s) after a failure or precautionary shutdown of an engine. It must be shown that following application of 30-second OEI power, any damage will be readily detectable by the applicable inspections and other related procedures furnished in accordance with paragraph A29.4 of [Appendix A](#_DxCrossRefBm1178331851) of CS-29. The use of 30-second OEI power must be limited to not more than 30 seconds for any period in which the power is used and by: (1) The maximum rotational speed which may not be greater than: (i) The maximum value determined by the rotor design: or (ii) The maximum value demonstrated during the type tests; (2) The maximum allowable gas temperature; and (3) The maximum allowable torque. (j) Rated 2-minute OEI power operation. Rated 2-minute OEI power is permitted only on multi-engine, turbine-powered rotorcraft, also certificated for the use of rated 30-second OEI power, and can only be used for continued operation of the remaining engine(s) after a failure or precautionary shutdown of an engine. It must be shown that following application of 2-minute OEI power, any damage will be readily detectable by the applicable inspections and other related procedures furnished in accordance with paragraph A29.4 of [Appendix A](#_DxCrossRefBm1178331851) of CS-29. The use of 2-minute OEI power must be limited to not more than 2 minutes for any period in which that power is used, and by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor designs; or (ii) The maximum value demonstrated during the type tests; (2) The maximum allowable gas temperature; and (3) The maximum allowable torque.
#### CS 29.1521 Powerplant limitations *ED Decision 2003/16/RM* (a) *General*. The powerplant limitations prescribed in this paragraph must be established so that they do not exceed the corresponding limits for which the engines are type certificated. (b) *Take-off operation.* The powerplant take- off operation must be limited by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor design; or (ii) The maximum value shown during the type tests; (2) The maximum allowable manifold pressure (for reciprocating engines); (3) The maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (4) The maximum allowable power or torque for each engine, considering the power input limitations of the transmission with all engines operating; (5) The maximum allowable power or torque for each engine considering the power input limitations of the transmission with one engine inoperative; (6) The time limit for the use of the power corresponding to the limitations established in sub-paragraphs (b)(1) to (5); and (7) If the time limit established in sub-paragraph (b)(6) exceeds 2 minutes: (i) The maximum allowable cylinder head or coolant outlet temperature (for reciprocating engines); and (ii) The maximum allowable engine and transmission oil temperatures. (c) *Continuous operation.* The continuous operation must be limited by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor design; or (ii) The maximum value shown during the type tests; (2) The minimum rotational speed shown under the rotor speed requirements in [CS 29.1509(c)](#_DxCrossRefBm1685772664); (3) The maximum allowable manifold pressure (for reciprocating engines); (4) The maximum allowable turbine inlet or turbine outlet gas temperature (for turbine engines); (5) The maximum allowable power or torque for each engine, considering the power input limitations of the transmission with all engines operating; (6) The maximum allowable power or torque for each engine, considering the power input limitations of the transmission with one engine inoperative; and (7) The maximum allowable temperatures for – (i) The cylinder head or coolant outlet (for reciprocating engines); (ii) The engine oil; and (iii) The transmission oil. (d) *Fuel grade or designation.* The minimum fuel grade (for reciprocating engines) or fuel designation (for turbine engines) must be established so that it is not less than that required for the operation of the engines within the limitations in sub-paragraphs (b) and (c). (e) *Ambient temperature.* Ambient temperature limitations (including limitations for winterization installations if applicable) must be established as the maximum ambient atmospheric temperature at which compliance with the cooling provisions of [CS 29.1041](#_DxCrossRefBm1685772506) to [29.1049](#_DxCrossRefBm1685772505) is shown. (f) *Two and one-half minute OEI power operation.* Unless otherwise authorised, the use of 2½-minute OEI power must be limited to engine failure operation of multi-engine, turbine powered rotorcraft for not longer than 2½ minutes for any period in which that power is used. The use of 2½-minute OEI power must also be limited by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor design; or (ii) The maximum value shown during the type tests; (2) The maximum allowable gas temperature; (3) The maximum allowable torque; and (4) The maximum allowable oil temperature. (g) *Thirty-minute OEI power operation.* Unless otherwise authorised, the use of 30-minute OEI power must be limited to multi-engine, turbine-powered rotorcraft for not longer than 30 minutes after failure of an engine. The use of 30-minute OEI power must also be limited by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor design; or (ii) The maximum value shown during the type tests; (2) The maximum allowable gas temperature; (3) The maximum allowable torque; and (4) The maximum allowable oil temperature. (h) *Continuous OEI power operation.* Unless otherwise authorised, the use of continuous OEI power must be limited to multi-engine, turbine- powered rotorcraft for continued flight after failure of an engine. The use of continuous OEI power must also be limited by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor design; or (ii) The maximum value shown during the type tests. (2) The maximum allowable gas temperature; (3) The maximum allowable torque; and (4) The maximum allowable oil temperature. (i) *Rated 30-second OEI power operation.* Rated 30-second OEI power is permitted only on multi-engine, turbine-powered rotorcraft also certificated for the use of rated 2-minute OEI power, and can only be used for continued operation of the remaining engine(s) after a failure or precautionary shutdown of an engine. It must be shown that following application of 30-second OEI power, any damage will be readily detectable by the applicable inspections and other related procedures furnished in accordance with paragraph A29.4 of [Appendix A](#_DxCrossRefBm1685772316) of CS-29. The use of 30-second OEI power must be limited to not more than 30 seconds for any period in which the power is used and by: (1) The maximum rotational speed which may not be greater than: (i) The maximum value determined by the rotor design: or (ii) The maximum value demonstrated during the type tests; (2) The maximum allowable gas temperature; and (3) The maximum allowable torque. (j) *Rated 2-minute OEI power operation.* Rated 2-minute OEI power is permitted only on multi-engine, turbine-powered rotorcraft, also certificated for the use of rated 30-second OEI power, and can only be used for continued operation of the remaining engine(s) after a failure or precautionary shutdown of an engine. It must be shown that following application of 2-minute OEI power, any damage will be readily detectable by the applicable inspections and other related procedures furnished in accordance with paragraph A29.4 of [Appendix A](#_DxCrossRefBm1685772316) of CS-29. The use of 2-minute OEI power must be limited to not more than 2 minutes for any period in which that power is used, and by: (1) The maximum rotational speed, which may not be greater than: (i) The maximum value determined by the rotor designs; or (ii) The maximum value demonstrated during the type tests; (2) The maximum allowable gas temperature; and (3) The maximum allowable torque.