CS 29.1389 Position light distribution and intensities
Available versions for ERULES-1963177438-5675
ED Decision 2003/16/RM
found in: CS-29 Amdt 10 - Large Rotercraft (Jan 2023)
From
CS-29 Amdt 12 - La... (Mar 2026)
CS-29 Amdt 11 - La... (Feb 2023)
CS-29 Amdt 10 - La... (Jan 2023)
From section
To
CS-29 Amdt 12 - La... (Mar 2026)
CS-29 Amdt 11 - La... (Feb 2023)
CS-29 Amdt 10 - La... (Jan 2023)
To section
No visible text changes
0 removals
0 additions
View
Rich
Plain
Sync scrolling
Share
From
Show details
Hide details
To
Show details
Hide details
Version
Show side by side
CS 29.1389 Position light distribution and intensities ED Decision 2003/16/RM (a) General. The intensities prescribed in this paragraph must be provided by new equipment with light covers and colour filters in place. Intensities must be determined with the light source operating at a steady value equal to the average luminous output of the source at the normal operating voltage of the rotorcraft. The light distribution and intensity of each position light must meet the requirements of sub-paragraph (b). (b) Forward and rear position lights. The light distribution and intensities of forward and rear position lights must be expressed in terms of minimum intensities in the horizontal plane, minimum intensities in any vertical plane, and maximum intensities in overlapping beams, within dihedral angles, L, R and A, and must meet the following requirements: (1) Intensities in the horizontal plane. Each intensity in the horizontal plane (the plane containing the longitudinal axis of the rotorcraft and perpendicular to the plane of symmetry of the rotorcraft), must equal or exceed the values in [CS 29.1391](#_DxCrossRefBm1513259740). (2) Intensities in the vertical plane. Each intensity in any vertical plane (the plane perpendicular to the horizontal plane) must equal or exceed the appropriate value in [CS 29.1393](#_DxCrossRefBm1513259739) where I is the minimum intensity prescribed in [CS 29.1391](#_DxCrossRefBm1513259740) for the corresponding angles in the horizontal plane. (3) Intensities in overlaps between adjacent signals. No intensity in any overlap between adjacent signals may exceed the values in [CS 29.1395](#_DxCrossRefBm1513259741), except that higher intensities in overlaps may be used with the use of main beam intensities substantially greater than the minima specified in [CS 29.1391](#_DxCrossRefBm1513259740) and [29.1393](#_DxCrossRefBm1513259739) if the overlap intensities in relation to the main beam intensities do not adversely affect signal clarity.
CS 29.1389 Position light distribution and intensities ED Decision 2003/16/RM (a) General. The intensities prescribed in this paragraph must be provided by new equipment with light covers and colour filters in place. Intensities must be determined with the light source operating at a steady value equal to the average luminous output of the source at the normal operating voltage of the rotorcraft. The light distribution and intensity of each position light must meet the requirements of sub-paragraph (b). (b) Forward and rear position lights. The light distribution and intensities of forward and rear position lights must be expressed in terms of minimum intensities in the horizontal plane, minimum intensities in any vertical plane, and maximum intensities in overlapping beams, within dihedral angles, L, R and A, and must meet the following requirements: (1) Intensities in the horizontal plane. Each intensity in the horizontal plane (the plane containing the longitudinal axis of the rotorcraft and perpendicular to the plane of symmetry of the rotorcraft), must equal or exceed the values in [CS 29.1391](#_DxCrossRefBm1178332154). (2) Intensities in the vertical plane. Each intensity in any vertical plane (the plane perpendicular to the horizontal plane) must equal or exceed the appropriate value in [CS 29.1393](#_DxCrossRefBm1178332153) where I is the minimum intensity prescribed in [CS 29.1391](#_DxCrossRefBm1178332154) for the corresponding angles in the horizontal plane. (3) Intensities in overlaps between adjacent signals. No intensity in any overlap between adjacent signals may exceed the values in [CS 29.1395](#_DxCrossRefBm1178332155), except that higher intensities in overlaps may be used with the use of main beam intensities substantially greater than the minima specified in [CS 29.1391](#_DxCrossRefBm1178332154) and [29.1393](#_DxCrossRefBm1178332153) if the overlap intensities in relation to the main beam intensities do not adversely affect signal clarity.
#### CS 29.1389 Position light distribution and intensities *ED Decision 2003/16/RM* (a) *General*. The intensities prescribed in this paragraph must be provided by new equipment with light covers and colour filters in place. Intensities must be determined with the light source operating at a steady value equal to the average luminous output of the source at the normal operating voltage of the rotorcraft. The light distribution and intensity of each position light must meet the requirements of sub-paragraph (b). (b) *Forward and rear position lights.* The light distribution and intensities of forward and rear position lights must be expressed in terms of minimum intensities in the horizontal plane, minimum intensities in any vertical plane, and maximum intensities in overlapping beams, within dihedral angles, L, R and A, and must meet the following requirements: (1) *Intensities in the horizontal plane.* Each intensity in the horizontal plane (the plane containing the longitudinal axis of the rotorcraft and perpendicular to the plane of symmetry of the rotorcraft), must equal or exceed the values in [CS 29.1391](#_DxCrossRefBm1685772619). (2) *Intensities in the vertical plane.* Each intensity in any vertical plane (the plane perpendicular to the horizontal plane) must equal or exceed the appropriate value in [CS 29.1393](#_DxCrossRefBm1685772618) where I is the minimum intensity prescribed in [CS 29.1391](#_DxCrossRefBm1685772619) for the corresponding angles in the horizontal plane. (3) *Intensities in overlaps between adjacent signals.* No intensity in any overlap between adjacent signals may exceed the values in [CS 29.1395](#_DxCrossRefBm1685772620), except that higher intensities in overlaps may be used with the use of main beam intensities substantially greater than the minima specified in [CS 29.1391](#_DxCrossRefBm1685772619) and [29.1393](#_DxCrossRefBm1685772618) if the overlap intensities in relation to the main beam intensities do not adversely affect signal clarity.