CS 29.971 Fuel tank sump
Available versions for ERULES-1963177438-5633
ED Decision 2003/16/RM
found in: CS-29 Amdt 11 - Large Rotercraft (Feb 2023)
From
CS-29 Amdt 12 - La... (Mar 2026)
CS-29 Amdt 11 - La... (Feb 2023)
CS-29 Amdt 10 - La... (Jan 2023)
From section
To
CS-29 Amdt 12 - La... (Mar 2026)
CS-29 Amdt 11 - La... (Feb 2023)
CS-29 Amdt 10 - La... (Jan 2023)
To section
No visible text changes
0 removals
0 additions
View
Rich
Plain
Sync scrolling
Share
From
Show details
Hide details
To
Show details
Hide details
Version
Show side by side
CS 29.971 Fuel tank sump ED Decision 2003/16/RM (a) Each fuel tank must have a sump with a capacity of not less than the greater of: (1) 0.10% of the tank capacity; or (2) 0.24 litres (0.05 Imperial gallon/one sixteenth US gallon). (b) The capacity prescribed in sub-paragraph (a) must be effective with the rotorcraft in any normal attitude, and must be located so that the sump contents cannot escape through the tank outlet opening. (c) Each fuel tank must allow drainage of hazardous quantities of water from each part of the tank to the sump with the rotorcraft in any ground attitude to be expected in service. (d) Each fuel tank sump must have a drain that allows complete drainage of the sump on the ground.
CS 29.971 Fuel tank sump ED Decision 2003/16/RM (a) Each fuel tank must have a sump with a capacity of not less than the greater of: (1) 0.10% of the tank capacity; or (2) 0.24 litres (0.05 Imperial gallon/one sixteenth US gallon). (b) The capacity prescribed in sub-paragraph (a) must be effective with the rotorcraft in any normal attitude, and must be located so that the sump contents cannot escape through the tank outlet opening. (c) Each fuel tank must allow drainage of hazardous quantities of water from each part of the tank to the sump with the rotorcraft in any ground attitude to be expected in service. (d) Each fuel tank sump must have a drain that allows complete drainage of the sump on the ground.
#### CS 29.971 Fuel tank sump *ED Decision 2003/16/RM* (a) Each fuel tank must have a sump with a capacity of not less than the greater of: (1) 0.10% of the tank capacity; or (2) 0.24 litres (0.05 Imperial gallon/one sixteenth US gallon). (b) The capacity prescribed in sub-paragraph (a) must be effective with the rotorcraft in any normal attitude, and must be located so that the sump contents cannot escape through the tank outlet opening. (c) Each fuel tank must allow drainage of hazardous quantities of water from each part of the tank to the sump with the rotorcraft in any ground attitude to be expected in service. (d) Each fuel tank sump must have a drain that allows complete drainage of the sump on the ground.