Light
Dark
System
Log In
Loading...
Compare / EASA/
Incorporated Amendments
/
Compare & Highlight Differences
CS 29.1125 Exhaust heat exchangers
Available versions for ERULES-1963177438-5531
ED Decision 2003/16/RM
found in: CS-29 Amdt 10 - Large Rotercraft (Jan 2023)
From
CS-29 Amdt 12 - La... (Mar 2026)
CS-29 Amdt 11 - La... (Feb 2023)
CS-29 Amdt 10 - La... (Jan 2023)
From section
To
CS-29 Amdt 12 - La... (Mar 2026)
CS-29 Amdt 11 - La... (Feb 2023)
CS-29 Amdt 10 - La... (Jan 2023)
To section
No visible text changes
0 removals
0 additions
View
Rich
Plain
Sync scrolling
Share
From
Show details
Hide details
To
Show details
Hide details
Version
Show side by side
CS 29.1125 Exhaust heat exchangers ED Decision 2003/16/RM For reciprocating engine powered rotorcraft the following apply: (a) Each exhaust heat exchanger must be constructed and installed to withstand the vibration, inertia, and other loads to which it would be subjected in operation. In addition: (1) Each exchanger must be suitable for continued operation at high temperatures and resistant to corrosion from exhaust gases; (2) There must be means for inspecting the critical parts of each exchanger; (3) Each exchanger must have cooling provisions wherever it is subject to contact with exhaust gases; and (4) No exhaust heat exchanger or muff may have stagnant areas or liquid traps that would increase the probability of ignition of flammable fluids or vapours that might be present in case of the failure or malfunction of components carrying flammable fluids. (b) If an exhaust heat exchanger is used for heating ventilating air used by personnel – (1) There must be a secondary heat exchanger between the primary exhaust gas heat exchanger and the ventilating air system; or (2) Other means must be used to prevent harmful contamination of the ventilating air.
CS 29.1125 Exhaust heat exchangers ED Decision 2003/16/RM For reciprocating engine powered rotorcraft the following apply: (a) Each exhaust heat exchanger must be constructed and installed to withstand the vibration, inertia, and other loads to which it would be subjected in operation. In addition: (1) Each exchanger must be suitable for continued operation at high temperatures and resistant to corrosion from exhaust gases; (2) There must be means for inspecting the critical parts of each exchanger; (3) Each exchanger must have cooling provisions wherever it is subject to contact with exhaust gases; and (4) No exhaust heat exchanger or muff may have stagnant areas or liquid traps that would increase the probability of ignition of flammable fluids or vapours that might be present in case of the failure or malfunction of components carrying flammable fluids. (b) If an exhaust heat exchanger is used for heating ventilating air used by personnel – (1) There must be a secondary heat exchanger between the primary exhaust gas heat exchanger and the ventilating air system; or (2) Other means must be used to prevent harmful contamination of the ventilating air.
#### CS 29.1125 Exhaust heat exchangers *ED Decision 2003/16/RM* For reciprocating engine powered rotorcraft the following apply: (a) Each exhaust heat exchanger must be constructed and installed to withstand the vibration, inertia, and other loads to which it would be subjected in operation. In addition: (1) Each exchanger must be suitable for continued operation at high temperatures and resistant to corrosion from exhaust gases; (2) There must be means for inspecting the critical parts of each exchanger; (3) Each exchanger must have cooling provisions wherever it is subject to contact with exhaust gases; and (4) No exhaust heat exchanger or muff may have stagnant areas or liquid traps that would increase the probability of ignition of flammable fluids or vapours that might be present in case of the failure or malfunction of components carrying flammable fluids. (b) If an exhaust heat exchanger is used for heating ventilating air used by personnel – (1) There must be a secondary heat exchanger between the primary exhaust gas heat exchanger and the ventilating air system; or (2) Other means must be used to prevent harmful contamination of the ventilating air.