Light
Dark
System
Log In
Loading...
Compare / EASA/
Incorporated Amendments
/
Compare & Highlight Differences
CS 29.1013 Oil tanks
Available versions for ERULES-1963177438-5443
ED Decision 2003/16/RM
found in: CS-29 Amdt 10 - Large Rotercraft (Jan 2023)
From
CS-29 Amdt 12 - La... (Mar 2026)
CS-29 Amdt 11 - La... (Feb 2023)
CS-29 Amdt 10 - La... (Jan 2023)
From section
To
CS-29 Amdt 12 - La... (Mar 2026)
CS-29 Amdt 11 - La... (Feb 2023)
CS-29 Amdt 10 - La... (Jan 2023)
To section
No visible text changes
0 removals
0 additions
View
Rich
Plain
Sync scrolling
Share
From
Show details
Hide details
To
Show details
Hide details
Version
Show side by side
CS 29.1013 Oil tanks ED Decision 2003/16/RM (a) Installation. Each oil tank installation must meet the requirements of [CS 29.967](#_DxCrossRefBm1513259616). (b) Expansion space. Oil tank expansion space must be provided so that – (1) Each oil tank used with a reciprocating engine has an expansion space of not less than the greater of 10% of the tank capacity or 1.9 litres (0.42 Imperial gallon/0.5 US gallon), and each oil tank used with a turbine engine has an expansion space of not less than 10% of the tank capacity; (2) Each reserve oil tank not directly connected to any engine has an expansion space of not less than 2% of the tank capacity; and (3) It is impossible to fill the expansion space inadvertently with the rotorcraft in the normal ground attitude. (c) Filler connections. Each recessed oil tank filler connection that can retain any appreciable quantity of oil must have a drain that discharges clear of the entire rotorcraft. In addition – (1) Each oil tank filler cap must provide an oil-tight seal under the pressure expected in operation; (2) For Category A rotorcraft, each oil tank filler cap or filler cap cover must incorporate features that provide a warning when caps are not fully locked or seated on the filler connection; and (3) Each oil filler must be marked under [CS 29.1557(c)(2)](#_DxCrossRefBm1513259621). (d) Vent. Oil tanks must be vented as follows: (1) Each oil tank must be vented from the top part of the expansion space so that venting is effective under all normal flight conditions. (2) Oil tank vents must be arranged so that condensed water vapour that might freeze and obstruct the line cannot accumulate at any point. (e) Outlet. There must be means to prevent entrance into the tank itself, or into the tank outlet, of any object that might obstruct the flow of oil through the system. No oil tank outlet may be enclosed by a screen or guard that would reduce the flow of oil below a safe value at any operating temperature. There must be a shutoff valve at the outlet of each oil tank used with a turbine engine unless the external portion of the oil system (including oil tank supports) is fireproof. (f) Flexible liners. Each flexible oil tank liner must be approved or shown to be suitable for the particular installation.
CS 29.1013 Oil tanks ED Decision 2003/16/RM (a) Installation. Each oil tank installation must meet the requirements of [CS 29.967](#_DxCrossRefBm1178332023). (b) Expansion space. Oil tank expansion space must be provided so that – (1) Each oil tank used with a reciprocating engine has an expansion space of not less than the greater of 10% of the tank capacity or 1.9 litres (0.42 Imperial gallon/0.5 US gallon), and each oil tank used with a turbine engine has an expansion space of not less than 10% of the tank capacity; (2) Each reserve oil tank not directly connected to any engine has an expansion space of not less than 2% of the tank capacity; and (3) It is impossible to fill the expansion space inadvertently with the rotorcraft in the normal ground attitude. (c) Filler connections. Each recessed oil tank filler connection that can retain any appreciable quantity of oil must have a drain that discharges clear of the entire rotorcraft. In addition – (1) Each oil tank filler cap must provide an oil-tight seal under the pressure expected in operation; (2) For Category A rotorcraft, each oil tank filler cap or filler cap cover must incorporate features that provide a warning when caps are not fully locked or seated on the filler connection; and (3) Each oil filler must be marked under [CS 29.1557(c)(2)](#_DxCrossRefBm1178332028). (d) Vent. Oil tanks must be vented as follows: (1) Each oil tank must be vented from the top part of the expansion space so that venting is effective under all normal flight conditions. (2) Oil tank vents must be arranged so that condensed water vapour that might freeze and obstruct the line cannot accumulate at any point. (e) Outlet. There must be means to prevent entrance into the tank itself, or into the tank outlet, of any object that might obstruct the flow of oil through the system. No oil tank outlet may be enclosed by a screen or guard that would reduce the flow of oil below a safe value at any operating temperature. There must be a shutoff valve at the outlet of each oil tank used with a turbine engine unless the external portion of the oil system (including oil tank supports) is fireproof. (f) Flexible liners. Each flexible oil tank liner must be approved or shown to be suitable for the particular installation.
#### CS 29.1013 Oil tanks *ED Decision 2003/16/RM* (a) *Installation*. Each oil tank installation must meet the requirements of [CS 29.967](#_DxCrossRefBm1685772488). (b) *Expansion space.* Oil tank expansion space must be provided so that – (1) Each oil tank used with a reciprocating engine has an expansion space of not less than the greater of 10% of the tank capacity or 1.9 litres (0.42 Imperial gallon/0.5 US gallon), and each oil tank used with a turbine engine has an expansion space of not less than 10% of the tank capacity; (2) Each reserve oil tank not directly connected to any engine has an expansion space of not less than 2% of the tank capacity; and (3) It is impossible to fill the expansion space inadvertently with the rotorcraft in the normal ground attitude. (c) *Filler connections.* Each recessed oil tank filler connection that can retain any appreciable quantity of oil must have a drain that discharges clear of the entire rotorcraft. In addition – (1) Each oil tank filler cap must provide an oil-tight seal under the pressure expected in operation; (2) For Category A rotorcraft, each oil tank filler cap or filler cap cover must incorporate features that provide a warning when caps are not fully locked or seated on the filler connection; and (3) Each oil filler must be marked under [CS 29.1557(c)(2)](#_DxCrossRefBm1685772493). (d) *Vent*. Oil tanks must be vented as follows: (1) Each oil tank must be vented from the top part of the expansion space so that venting is effective under all normal flight conditions. (2) Oil tank vents must be arranged so that condensed water vapour that might freeze and obstruct the line cannot accumulate at any point. (e) *Outlet*. There must be means to prevent entrance into the tank itself, or into the tank outlet, of any object that might obstruct the flow of oil through the system. No oil tank outlet may be enclosed by a screen or guard that would reduce the flow of oil below a safe value at any operating temperature. There must be a shutoff valve at the outlet of each oil tank used with a turbine engine unless the external portion of the oil system (including oil tank supports) is fireproof. (f) *Flexible liners.* Each flexible oil tank liner must be approved or shown to be suitable for the particular installation.