AMC 22.1549(d) Power-plant instruments
Available versions for ERULES-1963177438-5307
ED Decision 2003/13/RM
found in: Sailplane Rule Book - Part-SAO Part-SFCL CS-22 (Nov 2022)
Version
Sailplane Rule Boo... (Nov 2022)
Section
Share
Version
Show details
Hide details
Version
AMC 22.1549(d) Power-plant instruments ED Decision 2003/13/RM In the case of digital solid state displays the required red line should be represented by a steady red light near or on the instrument, or by blinking of the whole display. The precautionary range should be indicated near or on the instrument. All instrument indications in that range should be designed to obtain the attention of the pilot. In addition, the operating range data should be placarded near the display using the colours described in [CS 22.1549(a), (b) and (c)](#_DxCrossRefBm2056272363). Oil temperature, oil pressure and cylinder head temperature indications will be acceptable if achieved by means of warning lights instead of analogue or digital indications if: (1) The required red line is represented by a steady red light. (2) The normal operating range is represented by a steady green light. (3) The precautionary range is represented by a steady yellow light. (4) A ‘press to test’ facility is provided for the warning light displays.