Light
Dark
System
Log In
Loading...
Compare / EASA/
Incorporated Amendments
/
Compare & Highlight Differences
AMC 22.307(a) Proof of structure
Available versions for ERULES-1963177438-5265
ED Decision 2003/13/RM
found in: Sailplane Rule Book - Part-SAO Part-SFCL CS-22 (Nov 2022)
Version
Sailplane Rule Boo... (Nov 2022)
Section
Share
Version
Show details
Hide details
Version
AMC 22.307(a) Proof of structure ED Decision 2003/13/RM (1) Substantiating load tests made in accordance with [CS 22.307(a)](#_DxCrossRefBm2056272101) should normally be taken to ultimate design load. (2) The results obtained from strength tests should be so corrected for departures from the mechanical properties and dimensions assumed in the design calculations as to establish that the possibility of any structure having a strength less than the design value, owing to material and dimensional variation, is extremely remote.