CS 22.1017 Oil lines and fittings
Available versions for ERULES-1963177438-5133
ED Decision 2003/13/RM
found in: Sailplane Rule Book - Part-SAO Part-SFCL CS-22 (Nov 2022)
Version
Sailplane Rule Boo... (Nov 2022)
Section
Share
Version
Show details
Hide details
Version
CS 22.1017 Oil lines and fittings ED Decision 2003/13/RM (a) Oil lines must comply with [CS 22.993](#_DxCrossRefBm2056272292) and each oil line and fitting must be made of fireproof material. (b) *Breather lines.* Breather lines must be arranged so that: (1) condensed water vapour or oil that might freeze and obstruct the line cannot accumulate at any point; (2) the breather discharge will not constitute a fire hazard if foaming occurs or cause emitted oil to strike the pilot’s wind shields; (3) the breather does not discharge into the engine air induction system; (4) if the engine is retractable, there must be no discharge of oil from the breather line when the engine is completely retracted.