CS 22.893 Water ballast tank installation
Available versions for ERULES-1963177438-5104
ED Decision 2003/13/RM
found in: Sailplane Rule Book - Part-SAO Part-SFCL CS-22 (Nov 2022)
Version
Sailplane Rule Boo... (Nov 2022)
Section
Share
Version
Show details
Hide details
Version
CS 22.893 Water ballast tank installation ED Decision 2003/13/RM (a) General. The surrounding aircraft structure must be appropriately protected from any likely damage (corrosion, debonding, etc.) from water ballast leaks. (b) Water ballast tanks which are not an integral part of the structure must be supported so that the loads resulting from the mass of the water ballast are not concentrated. In addition: (1) Means must be provided to prevent chafing between each tank and the supporting structure. (2) Each tank compartment must be vented and drained (c) For integral tanks the surrounding structure must either be shown to be impervious to ballast absorption, or suitably protected.