CS 22.857 Electrical bonding
Available versions for ERULES-1963177438-5097
ED Decision 2003/13/RM
found in: Sailplane Rule Book - Part-SAO Part-SFCL CS-22 (Nov 2022)
Version
Sailplane Rule Boo... (Nov 2022)
Section
Share
Version
Show details
Hide details
Version
CS 22.857 Electrical bonding ED Decision 2003/13/RM (a) Electrical continuity must be provided to prevent the existence of differences of potential between components of the powerplant including fuel and other tanks, and other significant parts of the powered sailplane which are electrically conductive. (b) If the sailplane is equipped for winch or auto launching, electrical continuity must be provided between the metallic parts of the cable release mechanism and the control column. (c) The cross-sectional area of bonding connectors, if made from copper, must not be less than 1.33 mm2.