CS 27.1357 Circuit protective devices
Available versions for ERULES-1963177438-4812
ED Decision 2003/15/RM
found in: CS-27 Amdt 9 - Small Rotorcraft (Dec 2021)
From
CS-27 Amdt 10 - Sm... (Feb 2023)
CS-27 Amdt 9 - Sma... (Dec 2021)
From section
To
CS-27 Amdt 10 - Sm... (Feb 2023)
CS-27 Amdt 9 - Sma... (Dec 2021)
To section
No visible text changes
0 removals
0 additions
View
Rich
Plain
Sync scrolling
Share
From
Show details
Hide details
To
Show details
Hide details
Version
Show side by side
CS 27.1357 Circuit protective devices ED Decision 2003/15/RM (a) Protective devices, such as fuses or circuit breakers, must be installed in each electrical circuit other than: (1) The main circuits of starter motors; and (2) Circuits in which no hazard is presented by their omission. (b) A protective device for a circuit essential to flight safety may not be used to protect any other circuit. (c) Each resettable circuit protective device (‘trip free’ device in which the tripping mechanism cannot be overridden by the operating control) must be designed so that: (1) A manual operation is required to restore service after tripping; and (2) If an overload or circuit fault exists, the device will open the circuit regardless of the position of the operating control. (d) If the ability to reset a circuit breaker or replace a fuse is essential to safety in flight, that circuit breaker or fuse must be located and identified so that it can be readily reset or replaced in flight. (e) If fuses are used, there must be one spare of each rating, or 50% spare fuses of each rating, whichever is greater.
CS 27.1357 Circuit protective devices ED Decision 2003/15/RM (a) Protective devices, such as fuses or circuit breakers, must be installed in each electrical circuit other than: (1) The main circuits of starter motors; and (2) Circuits in which no hazard is presented by their omission. (b) A protective device for a circuit essential to flight safety may not be used to protect any other circuit. (c) Each resettable circuit protective device (‘trip free’ device in which the tripping mechanism cannot be overridden by the operating control) must be designed so that: (1) A manual operation is required to restore service after tripping; and (2) If an overload or circuit fault exists, the device will open the circuit regardless of the position of the operating control. (d) If the ability to reset a circuit breaker or replace a fuse is essential to safety in flight, that circuit breaker or fuse must be located and identified so that it can be readily reset or replaced in flight. (e) If fuses are used, there must be one spare of each rating, or 50% spare fuses of each rating, whichever is greater.