21.A.33 Inspections and tests
Available versions for ERULES-1963177438-3685
Regulation (EU) 2019/897
found in: Initial Airworthiness and Environmental Protection (748/2012) Part-21 Part-21L (Jul 2024)
Regulation (EU) 2024/1108
found in: Initial Airworthiness and Environmental Protection (748/2012) (Nov 2025)
From
Initial Airworthin... (Nov 2025)
Initial Airworthin... (Jul 2024)
From section
To
Initial Airworthin... (Nov 2025)
Initial Airworthin... (Jul 2024)
To section
No visible text changes
0 removals
0 additions
View
Rich
Plain
Sync scrolling
Share
From
Show details
Hide details
To
Show details
Hide details
Version
Show side by side
21.A.33 Inspections and tests Regulation (EU) 2019/897 (a) (Reserved) (b) Before each test is undertaken during the demonstration of compliance required by point [21.A.20](#_DxCrossRefBm1649096852), the applicant shall have verified: 1. for the test specimen, that: (i) the materials and processes adequately conform to the specifications for the proposed type design; (ii) the parts of the products adequately conform to the drawings in the proposed type design; and (iii) the manufacturing processes, construction and assembly adequately conform to those specified in the proposed type design; and 2. for the test and measuring equipment to be used for the test, that those are adequate for the test and appropriately calibrated. (c) On the basis of the verifications carried out in accordance with point (b), the applicant shall issue a statement of conformity listing any potential non-conformity, together with a justification that this will not affect the test results, and shall allow the Agency to make an inspection it considers necessary to check the validity of that statement. (d) The applicant shall allow the Agency to: 1. review any data and information related to the demonstration of compliance; and 2. witness or carry out any test or inspection conducted for the purpose of the demonstration of compliance. (e) For all the tests and inspections witnessed or carried out by the Agency in accordance with point (d)(2): 1. the applicant shall submit to the Agency a statement of conformity provided for in point (c); and 2. no change that affects the validity of the statement of conformity shall be made to the test specimen, or the test and measuring equipment, between the time the statement of conformity provided for in point (c) was issued and the time the test specimen is presented to the Agency for test.
#### 21.A.33 Inspections and tests *Regulation (EU) 2024/1108* (a) (Reserved) (b) Before each test is undertaken during the demonstration of compliance required by point [21.A.20](#_DxCrossRefBm485230342), the applicant shall have verified: 1. for the test specimen, that: (i) the materials and processes adequately conform to the specifications for the proposed type design; (ii) the parts of the products and the CMU components adequately conform to the drawings in the proposed type design; and (iii) the manufacturing processes, construction and assembly adequately conform to those specified in the proposed type design; and 2. for the test and measuring equipment to be used for the test, that those are adequate for the test and appropriately calibrated. (c) On the basis of the verifications carried out in accordance with point (b), the applicant shall issue a statement of conformity listing any potential non-conformity, together with a justification that this will not affect the test results, and shall allow the Agency to make an inspection it considers necessary to check the validity of that statement. (d) The applicant shall allow the Agency to: 1. review any data and information related to the demonstration of compliance; and 2. witness or carry out any test or inspection conducted for the purpose of the demonstration of compliance. (e) For all the tests and inspections witnessed or carried out by the Agency in accordance with point (d)(2): 1. the applicant shall submit to the Agency a statement of conformity provided for in point (c); and 2. no change that affects the validity of the statement of conformity shall be made to the test specimen, or the test and measuring equipment, between the time the statement of conformity provided for in point (c) was issued and the time the test specimen is presented to the Agency for test.