CS 26.155 Flammability of cargo compartment liners
Available versions for ERULES-1963177438-2932
ED Decision 2020/023/R
found in: CS-26 Additional Airworthiness Specifications for Operations (No 2015/640) Part-26 (Mar 2023)
From
CS-26 Additional A... (Oct 2025)
CS-26 Additional A... (Mar 2023)
From section
To
CS-26 Additional A... (Oct 2025)
CS-26 Additional A... (Mar 2023)
To section
No visible text changes
0 removals
0 additions
View
Rich
Plain
Sync scrolling
Share
From
Show details
Hide details
To
Show details
Hide details
Version
Show side by side
CS 26.155 Flammability of cargo compartment liners ED Decision 2020/023/R Compliance with point [26.155](#_DxCrossRefBm881534029) of Part-26 is demonstrated by complying with CS 25.855 & [Appendix F Part III](#_DxCrossRefBm881534143), or equivalent or with the following: (a) Large aeroplanes, Type Certificated after 1 January 1958, with Class C or D compartment, greater than 5.66 m3 (200 cubic feet) have ceiling and sidewall liner panels which are constructed of: (1) glass fibre reinforced resin, or (2) materials which meet the flame penetration test specifications of [Appendix F Part III](#_DxCrossRefBm881534143), or other equivalent methods, or (3) aluminium (only in the case of aluminium liner installations approved prior to 1 July 1989). (b) For compliance with this paragraph, the term ālinerā includes any design features, such as a joint or fastener which would affect the capability of the liner to safely contain a fire. [Issue: 26/3]
#### CS 26.155 Flammability of cargo compartment liners *ED Decision 2020/023/R* Compliance with point [26.155](#_DxCrossRefBm783605430) of Part-26 is demonstrated by complying with CS 25.855 & [AppendixĀ F PartĀ III](#_DxCrossRefBm783605543), or equivalent or with the following: (a) Large aeroplanes, Type Certificated after 1 January 1958, with Class C or D compartment, greater than 5.66Ā m3 (200 cubic feet) have ceiling and sidewall liner panels which are constructed of: (1) glass fibre reinforced resin, or (2) materials which meet the flame penetration test specifications of [Appendix F Part III](#_DxCrossRefBm783605543), or other equivalent methods, or (3) aluminium (only in the case of aluminium liner installations approved prior to 1 July 1989). (b) For compliance with this paragraph, the term ālinerā includes any design features, such as a joint or fastener which would affect the capability of the liner to safely contain a fire. [Issue: 26/2] [Issue: 26/3]