Light
Dark
System
Log In
Loading...
Compare / EASA/
Incorporated Amendments
/
Compare & Highlight Differences
CS ADR-DSN.S.880 Electrical power supply systems
Available versions for ERULES-1963177438-2331
ED Decision 2021/004/R
found in: Aerodromes (139/2014) Part-ADR.AR Part-ADR.OR Part-ADR.OPS CS-ADR-DSN CS-HPT-DSN (Jun 2023)
From
Easy Access Rules ... (Mar 2026)
Aerodromes (139/20... (Dec 2024)
Aerodromes (139/20... (Jun 2023)
From section
To
Easy Access Rules ... (Mar 2026)
Aerodromes (139/20... (Dec 2024)
Aerodromes (139/20... (Jun 2023)
To section
No visible text changes
0 removals
0 additions
View
Rich
Plain
Sync scrolling
Share
From
Show details
Hide details
To
Show details
Hide details
Version
Show side by side
CS ADR-DSN.S.880 Electrical power supply systems ED Decision 2021/004/R (a) For a precision approach runway, a secondary power supply capable of meeting the requirements of Table S-1 for the appropriate category of precision approach runway should be provided. Electric power supply connections to those facilities for which secondary power is required should be so arranged that the facilities are automatically connected to the secondary power supply on failure of the primary source of power. (b) For a runway meant for take-off in runway visual range conditions less than a value of 800 m, a secondary power supply capable of meeting the relevant requirements of Table S-1 should be provided. (c) At an aerodrome where the primary runway is a non-precision approach runway, a secondary power supply capable of meeting the requirements of Table S-1 should be provided except that a secondary power supply for visual aids need not be provided for more than one non-precision approach runway. (d) The following aerodrome facilities should be provided with a secondary power supply capable of supplying power when there is a failure of the primary power supply: (1) the signalling lamp and the minimum lighting necessary to enable air traffic services personnel to carry out their duties; (2) obstacle lights which are essential to ensure the safe operation of aircraft; (3) approach, runway and taxiway lighting as specified in [CS ADR-DSN.M.625](#_DxCrossRefBm1800047716) to [CS ADR‑DSN.M.745](#_DxCrossRefBm1800047778); (4) meteorological equipment; (5) essential equipment and facilities for the parking position if provided, in accordance with [CS ADR-DSN.M.750(a)](#_DxCrossRefBm1800047780) and [CS ADR-DSN.M.755(a)](#_DxCrossRefBm1800047782); and (6) illumination of apron areas over which passengers may walk. <table border="1" cellpadding="0" cellspacing="0" width="567"><tr><td valign="top" width="132"><p align="center"><b>Runway</b></p></td><td valign="top" width="265"><p align="center"><b>Lighting aids requiring power</b></p></td><td valign="top" width="170"><p align="center"><b>Maximum switch-over time</b></p></td></tr><tr><td valign="top" width="132"><p>Non-instrument</p></td><td valign="top" width="265"><p>Visual approach slope indicatorsa</p><p>Runway edgeb</p><p>Runway thresholdb</p><p>Runway endb</p><p>Obstaclea</p><p>Stopway end</p><p>Stopway edge</p></td><td valign="top" width="170"><p>See</p><p><a href="#_DxCrossRefBm1800047847">CS ADR-DSN.S.875(d)</a> and</p><p><a href="#_DxCrossRefBm1800047296">CS ADR-DSN.S.880(d)</a></p></td></tr><tr><td valign="top" width="132"><p>Non-precision approach</p></td><td valign="top" width="265"><p>Approach lighting system</p><p>Visual approach slope indicatorsa, d</p><p>Runway edged</p><p>Runway thresholdd</p><p>Runway endd</p><p>Obstaclea</p><p>Stopway end</p><p>Stopway edge</p></td><td valign="top" width="170"><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p></td></tr><tr><td valign="top" width="132"><p>Precision approach Category I</p></td><td valign="top" width="265"><p>Approach lighting system</p><p>Runway edged</p><p>Visual approach slope indicatorsa, d</p><p>Runway thresholdd</p><p>Runway end</p><p>Essential taxiwaya</p><p>Obstaclea</p><p>Stopway end</p><p>Stopway edge</p></td><td valign="top" width="170"><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p></td></tr><tr><td valign="top" width="132"><p>Precision approach Category II/III</p></td><td valign="top" width="265"><p>Inner 300 m of the approach lighting system</p><p>Other parts of the approach lighting system</p><p>Obstaclea</p><p>Runway edge</p><p>Runway threshold</p><p>Runway end</p><p>Runway centre line</p><p>Runway touchdown zone</p><p>Runway guard lights</p><p>All stop bars</p><p>Essential taxiway</p><p>Stopway end</p><p>Stopway edge</p></td><td valign="top" width="170"><p>1 second</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>1 second</p><p>1 second</p><p>1 second</p><p>1 second</p><p>15 seconds</p><p>1 second</p><p>15 seconds</p><p>1 second</p><p>15 seconds</p></td></tr><tr><td valign="top" width="132"><p>Runway meant for take-off in runway visual range</p><p>conditions less than a value of 800 m</p></td><td valign="top" width="265"><p>Runway edge</p><p>Runway end</p><p>Runway centre line</p><p>All stop bars</p><p>Essential taxiwaya</p><p>Obstaclea</p><p>Stopway end</p><p>Stopway edge</p></td><td valign="top" width="170"><p>15 secondsc</p><p>1 second</p><p>1 second</p><p>1 second</p><p>15 seconds</p><p>15 seconds</p><p>1 second</p><p>15 seconds</p></td></tr><tr><td colspan="3" valign="top" width="567"><p>a. Supplied with secondary power when their operation is essential to the safety of flight operation.</p><p>b. The use of emergency lighting should be in accordance with any procedures established.</p><p>c. One second where no runway centre line lights are provided.</p><p>d. One second where approaches are over hazardous or precipitous terrain.</p></td></tr></table> Table S-1. Secondary power supply requirements (see [***CS ADR-DSN.S.875(d)***](#_DxCrossRefBm1800047847)) [Issue: ADR-DSN/3] [Issue: ADR-DSN/4] [Issue: ADR-DSN/5]
CS ADR-DSN.S.880 Electrical power supply systems ED Decision 2021/004/R (a) For a precision approach runway, a secondary power supply capable of meeting the requirements of Table S-1 for the appropriate category of precision approach runway should be provided. Electric power supply connections to those facilities for which secondary power is required should be so arranged that the facilities are automatically connected to the secondary power supply on failure of the primary source of power. (b) For a runway meant for take-off in runway visual range conditions less than a value of 800 m, a secondary power supply capable of meeting the relevant requirements of Table S-1 should be provided. (c) At an aerodrome where the primary runway is a non-precision approach runway, a secondary power supply capable of meeting the requirements of Table S-1 should be provided except that a secondary power supply for visual aids need not be provided for more than one non-precision approach runway. (d) The following aerodrome facilities should be provided with a secondary power supply capable of supplying power when there is a failure of the primary power supply: (1) the signalling lamp and the minimum lighting necessary to enable air traffic services personnel to carry out their duties; (2) obstacle lights which are essential to ensure the safe operation of aircraft; (3) approach, runway and taxiway lighting as specified in [CS ADR-DSN.M.625](#_DxCrossRefBm151830854) to [CS ADR‑DSN.M.745](#_DxCrossRefBm151830916); (4) meteorological equipment; (5) essential equipment and facilities for the parking position if provided, in accordance with [CS ADR-DSN.M.750(a)](#_DxCrossRefBm151830918) and [CS ADR-DSN.M.755(a)](#_DxCrossRefBm151830920); and (6) illumination of apron areas over which passengers may walk. <table border="1" cellpadding="0" cellspacing="0" width="567"><tr><td valign="top" width="132"><p align="center"><b>Runway</b></p></td><td valign="top" width="265"><p align="center"><b>Lighting aids requiring power</b></p></td><td valign="top" width="170"><p align="center"><b>Maximum switch-over time</b></p></td></tr><tr><td valign="top" width="132"><p>Non-instrument</p></td><td valign="top" width="265"><p>Visual approach slope indicatorsa</p><p>Runway edgeb</p><p>Runway thresholdb</p><p>Runway endb</p><p>Obstaclea</p><p>Stopway end</p><p>Stopway edge</p></td><td valign="top" width="170"><p>See</p><p><a href="#_DxCrossRefBm151830985">CS ADR-DSN.S.875(d)</a> and</p><p><a href="#_DxCrossRefBm151830406">CS ADR-DSN.S.880(d)</a></p></td></tr><tr><td valign="top" width="132"><p>Non-precision approach</p></td><td valign="top" width="265"><p>Approach lighting system</p><p>Visual approach slope indicatorsa, d</p><p>Runway edged</p><p>Runway thresholdd</p><p>Runway endd</p><p>Obstaclea</p><p>Stopway end</p><p>Stopway edge</p></td><td valign="top" width="170"><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p></td></tr><tr><td valign="top" width="132"><p>Precision approach Category I</p></td><td valign="top" width="265"><p>Approach lighting system</p><p>Runway edged</p><p>Visual approach slope indicatorsa, d</p><p>Runway thresholdd</p><p>Runway end</p><p>Essential taxiwaya</p><p>Obstaclea</p><p>Stopway end</p><p>Stopway edge</p></td><td valign="top" width="170"><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p></td></tr><tr><td valign="top" width="132"><p>Precision approach Category II/III</p></td><td valign="top" width="265"><p>Inner 300 m of the approach lighting system</p><p>Other parts of the approach lighting system</p><p>Obstaclea</p><p>Runway edge</p><p>Runway threshold</p><p>Runway end</p><p>Runway centre line</p><p>Runway touchdown zone</p><p>Runway guard lights</p><p>All stop bars</p><p>Essential taxiway</p><p>Stopway end</p><p>Stopway edge</p></td><td valign="top" width="170"><p>1 second</p><p>15 seconds</p><p>15 seconds</p><p>15 seconds</p><p>1 second</p><p>1 second</p><p>1 second</p><p>1 second</p><p>15 seconds</p><p>1 second</p><p>15 seconds</p><p>1 second</p><p>15 seconds</p></td></tr><tr><td valign="top" width="132"><p>Runway meant for take-off in runway visual range</p><p>conditions less than a value of 800 m</p></td><td valign="top" width="265"><p>Runway edge</p><p>Runway end</p><p>Runway centre line</p><p>All stop bars</p><p>Essential taxiwaya</p><p>Obstaclea</p><p>Stopway end</p><p>Stopway edge</p></td><td valign="top" width="170"><p>15 secondsc</p><p>1 second</p><p>1 second</p><p>1 second</p><p>15 seconds</p><p>15 seconds</p><p>1 second</p><p>15 seconds</p></td></tr><tr><td colspan="3" valign="top" width="567"><p>a. Supplied with secondary power when their operation is essential to the safety of flight operation.</p><p>b. The use of emergency lighting should be in accordance with any procedures established.</p><p>c. One second where no runway centre line lights are provided.</p><p>d. One second where approaches are over hazardous or precipitous terrain.</p></td></tr></table> Table S-1. Secondary power supply requirements (see [***CS ADR-DSN.S.875(d)***](#_DxCrossRefBm151830985)) [Issue: ADR-DSN/3] [Issue: ADR-DSN/4] [Issue: ADR-DSN/5]
#### CS ADR-DSN.S.880 Electrical power supply systems *ED Decision 2021/004/R* (a) For a precision approach runway, a secondary power supply capable of meeting the requirements of Table S-1 for the appropriate category of precision approach runway should be provided. Electric power supply connections to those facilities for which secondary power is required should be so arranged that the facilities are automatically connected to the secondary power supply on failure of the primary source of power. (b) For a runway meant for take-off in runway visual range conditions less than a value of 800 m, a secondary power supply capable of meeting the relevant requirements of Table S-1 should be provided. (c) At an aerodrome where the primary runway is a non-precision approach runway, a secondary power supply capable of meeting the requirements of Table S-1 should be provided except that a secondary power supply for visual aids need not be provided for more than one non-precision approach runway. (d) The following aerodrome facilities should be provided with a secondary power supply capable of supplying power when there is a failure of the primary power supply: (1) the signalling lamp and the minimum lighting necessary to enable air traffic services personnel to carry out their duties; (2) obstacle lights which are essential to ensure the safe operation of aircraft; (3) approach, runway and taxiway lighting as specified in [CS ADR-DSN.M.625](#_DxCrossRefBm1262885293) to [CS ADR‑DSN.M.745](#_DxCrossRefBm1262885355); (4) meteorological equipment; (5) essential equipment and facilities for the parking position if provided, in accordance with [CS ADR-DSN.M.750(a)](#_DxCrossRefBm1262885357) and [CS ADR-DSN.M.755(a)](#_DxCrossRefBm1262885359); and (6) illumination of apron areas over which passengers may walk. <table bgcolor="#d9d9d9" cellpadding="7" cellspacing="0"> <col/> <col/> <col/> <tr valign="top"> <td bgcolor="#808080"><p align="center"> <b>Runway</b></p> </td> <td bgcolor="#808080"><p align="center"> <b>Lighting aids requiring power</b></p> </td> <td bgcolor="#808080"><p align="center"> <b>Maximum switch-over time</b></p> </td> </tr> <tr valign="top"> <td bgcolor="#d9d9d9"><p align="left"> Non-instrument</p> </td> <td bgcolor="#d9d9d9"><p align="left"> Visual approach slope indicators<sup>a</sup></p> <p align="left"> Runway edge<sup>b</sup></p> <p align="left"> Runway threshold<sup>b</sup></p> <p align="left"> Runway end<sup>b</sup></p> <p align="left"> Obstacle<sup>a</sup></p> <p align="left"> Stopway end</p> <p align="left"> Stopway edge</p> </td> <td bgcolor="#d9d9d9"><p align="left"> See</p> <p align="left"> <u><a href="#_DxCrossRefBm1262885424">CS ADR-DSN.S.875(d)</a></u> and</p> <p align="left"> <u><a href="#_DxCrossRefBm1262884852">CS ADR-DSN.S.880(d)</a></u> </p> </td> </tr> <tr valign="top"> <td bgcolor="#d9d9d9"><p align="left"> Non-precision approach</p> </td> <td bgcolor="#d9d9d9"><p align="left"> Approach lighting system</p> <p align="left"> Visual approach slope indicators<sup>a, d</sup></p> <p align="left"> Runway edge<sup>d</sup></p> <p align="left"> Runway threshold<sup>d</sup></p> <p align="left"> Runway end<sup>d</sup></p> <p align="left"> Obstacle<sup>a</sup></p> <p align="left"> Stopway end</p> <p align="left"> Stopway edge</p> </td> <td bgcolor="#d9d9d9"><p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> </td> </tr> <tr valign="top"> <td bgcolor="#d9d9d9"><p align="left"> Precision approach Category I</p> </td> <td bgcolor="#d9d9d9"><p align="left"> Approach lighting system</p> <p align="left"> Runway edge<sup>d</sup></p> <p align="left"> Visual approach slope indicators<sup>a, d</sup></p> <p align="left"> Runway threshold<sup>d</sup></p> <p align="left"> Runway end</p> <p align="left"> Essential taxiway<sup>a</sup></p> <p align="left"> Obstacle<sup>a</sup></p> <p align="left"> Stopway end</p> <p align="left"> Stopway edge</p> </td> <td bgcolor="#d9d9d9"><p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> </td> </tr> <tr valign="top"> <td bgcolor="#d9d9d9"><p align="left"> Precision approach Category II/III</p> </td> <td bgcolor="#d9d9d9"><p align="left"> Inner 300 m of the approach lighting system</p> <p align="left"> Other parts of the approach lighting system</p> <p align="left"> Obstacle<sup>a</sup></p> <p align="left"> Runway edge</p> <p align="left"> Runway threshold</p> <p align="left"> Runway end</p> <p align="left"> Runway centre line</p> <p align="left"> Runway touchdown zone</p> <p align="left"> Runway guard lights</p> <p align="left"> All stop bars</p> <p align="left"> Essential taxiway</p> <p align="left"> Stopway end</p> <p align="left"> Stopway edge</p> </td> <td bgcolor="#d9d9d9"><p align="left"> 1 second</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 1 second</p> <p align="left"> 1 second</p> <p align="left"> 1 second</p> <p align="left"> 1 second</p> <p align="left"> 15 seconds</p> <p align="left"> 1 second</p> <p align="left"> 15 seconds</p> <p align="left"> 1 second</p> <p align="left"> 15 seconds</p> </td> </tr> <tr valign="top"> <td bgcolor="#d9d9d9"><p align="left"> Runway meant for take-off in runway visual range</p> <p align="left"> conditions less than a value of 800 m</p> </td> <td bgcolor="#d9d9d9"><p align="left"> Runway edge</p> <p align="left"> Runway end</p> <p align="left"> Runway centre line</p> <p align="left"> All stop bars</p> <p align="left"> Essential taxiway<sup>a</sup></p> <p align="left"> Obstacle<sup>a</sup></p> <p align="left"> Stopway end</p> <p align="left"> Stopway edge</p> </td> <td bgcolor="#d9d9d9"><p align="left"> 15 seconds<sup>c</sup></p> <p align="left"> 1 second</p> <p align="left"> 1 second</p> <p align="left"> 1 second</p> <p align="left"> 15 seconds</p> <p align="left"> 15 seconds</p> <p align="left"> 1 second</p> <p align="left"> 15 seconds</p> </td> </tr> <tr> <td bgcolor="#d9d9d9" colspan="3" valign="top"><p> a. Supplied with secondary power when their operation is essential to the safety of flight operation.</p> <p> b. The use of emergency lighting should be in accordance with any procedures established.</p> <p> c. One second where no runway centre line lights are provided.</p> <p> d. One second where approaches are over hazardous or precipitous terrain.</p> </td> </tr> </table> ***Table S-1. Secondary power supply requirements (see*** [***CS ADR-DSN.S.875(d)***](#_DxCrossRefBm1262885424)***)*** [Issue: ADR-DSN/3] [Issue: ADR-DSN/4] [Issue: ADR-DSN/5]