AMC 25.793 and 25.810(c) Floor surfaces
Available versions for ERULES-1963177438-18712
ED Decision 2020/024/R
found in: CS-25 Amdt 27 - Large Aeroplanes (Jan 2023)
Version
CS-25 Amdt 27 - La... (Jan 2023)
Section
Share
Version
Show details
Hide details
Version
AMC 25.793 and 25.810(c) Floor surfaces ED Decision 2020/024/R The slip-resistant properties of floor surface material should be tested wet with the type of slippery liquid expected during operation. In addition, dry testing should also be conducted to provide reference friction values. In all the test conditions, the dynamic coefficient of friction (DCOF) should be at least 0.45. The following standard methods, using rubber and leather test devices, are acceptable (within their limitations) to conduct the testing: â Military Specifications MIL-W-5044B (dated 24 February 1964) and MIL-W-5044C (dated 25 August 1970), titled âWalkway Compound, Nonslip and Walkway Matting, Nonslipâ, â DIN 51131:2014-02, titled âTesting of floor coverings - Determination of the anti-slip property - Method for measurement of the sliding friction coefficientâ, â ISO 8295:1995, titled âPlastics - Film and sheeting - Determination of coefficients of frictionâ, â EN 13893:2002, titled âResilient, laminate and textile floor coverings - Measurement of dynamic coefficient of friction on dry floor surfacesâ, ANSI/NFSI B101.3-2012, titled âTest Method for Measuring Wet DCOF of Common Hard-Surface Floor Materialsâ. [Amdt 25/17] [Amdt 25/26]