Light
Dark
System
Log In
Loading...
Compare / EASA/
Incorporated Amendments
/
Compare & Highlight Differences
SPO.OP.195 Use of supplemental oxygen
Available versions for ERULES-1963177438-14059
Regulation (EU) No 379/2014
found in: Air Operations (965/2012) Part-ARO Part-ORO Part-CAT Part-SPA Part-NCC Part-NCO Part-SPO (Feb 2025)
From
Air Operations Rev... (Mar 2026)
Air Operations (96... (Feb 2025)
Air Operations (96... (Sep 2023)
From section
To
Air Operations Rev... (Mar 2026)
Air Operations (96... (Feb 2025)
Air Operations (96... (Sep 2023)
To section
No visible text changes
0 removals
0 additions
View
Rich
Plain
Sync scrolling
Share
From
Show details
Hide details
To
Show details
Hide details
Version
Show side by side
SPO.OP.195 Use of supplemental oxygen Regulation (EU) No 379/2014 (a) The operator shall ensure that task specialists and crew members use supplemental oxygen continuously whenever the cabin altitude exceeds 10 000 ft for a period of more than 30 minutes and whenever the cabin altitude exceeds 13 000 ft, unless otherwise approved by the competent authority and in accordance with SOPs. (b) Notwithstanding (a) and except for parachute operations, short excursions of a specified duration above 13 000 ft without using supplemental oxygen on other-than complex aeroplanes and helicopters may be undertaken with a prior approval of the competent authority based on the consideration of the following: (1) the duration of the excursion above 13 000 ft is not more than 10 minutes or, if needed for a longer period, the time strictly necessary to the accomplishment of the specialised task; (2) the flight is not conducted above 16 000 ft; (3) the safety briefing in accordance with [SPO.OP.135](#_DxCrossRefBm927680573) includes adequate information to crew members and tasks specialists on the effects of hypoxia; (4) SOPs for the concerned operation reflecting (1), (2) and (3); (5) the previous experience of the operator in conducting operations above 13 000 ft without using supplemental oxygen; (6) the individual experience of crew members and task specialists and their physiological adaptation to high altitudes; and (7) the altitude of the base where the operator is established or the operations are conducted from.
SPO.OP.195 Use of supplemental oxygen Regulation (EU) No 379/2014 (a) The operator shall ensure that task specialists and crew members use supplemental oxygen continuously whenever the cabin altitude exceeds 10 000 ft for a period of more than 30 minutes and whenever the cabin altitude exceeds 13 000 ft, unless otherwise approved by the competent authority and in accordance with SOPs. (b) Notwithstanding (a) and except for parachute operations, short excursions of a specified duration above 13 000 ft without using supplemental oxygen on other-than complex aeroplanes and helicopters may be undertaken with a prior approval of the competent authority based on the consideration of the following: (1) the duration of the excursion above 13 000 ft is not more than 10 minutes or, if needed for a longer period, the time strictly necessary to the accomplishment of the specialised task; (2) the flight is not conducted above 16 000 ft; (3) the safety briefing in accordance with [SPO.OP.135](#_DxCrossRefBm318088181) includes adequate information to crew members and tasks specialists on the effects of hypoxia; (4) SOPs for the concerned operation reflecting (1), (2) and (3); (5) the previous experience of the operator in conducting operations above 13 000 ft without using supplemental oxygen; (6) the individual experience of crew members and task specialists and their physiological adaptation to high altitudes; and (7) the altitude of the base where the operator is established or the operations are conducted from.
#### SPO.OP.195 Use of supplemental oxygen *Regulation (EU) No 379/2014* (a) The operator shall ensure that task specialists and crew members use supplemental oxygen continuously whenever the cabin altitude exceeds 10 000 ft for a period of more than 30 minutes and whenever the cabin altitude exceeds 13 000 ft, unless otherwise approved by the competent authority and in accordance with SOPs. (b) Notwithstanding (a) and except for parachute operations, short excursions of a specified duration above 13 000 ft without using supplemental oxygen on other-than complex aeroplanes and helicopters may be undertaken with a prior approval of the competent authority based on the consideration of the following: (1) the duration of the excursion above 13 000 ft is not more than 10 minutes or, if needed for a longer period, the time strictly necessary to the accomplishment of the specialised task; (2) the flight is not conducted above 16 000 ft; (3) the safety briefing in accordance with [SPO.OP.135](#_DxCrossRefBm523090177) includes adequate information to crew members and tasks specialists on the effects of hypoxia; (4) SOPs for the concerned operation reflecting (1), (2) and (3); (5) the previous experience of the operator in conducting operations above 13 000 ft without using supplemental oxygen; (6) the individual experience of crew members and task specialists and their physiological adaptation to high altitudes; and (7) the altitude of the base where the operator is established or the operations are conducted from.