Light
Dark
System
Log In
Loading...
Compare / EASA/
Incorporated Amendments
/
Compare & Highlight Differences
AMC1 MED.B.075 Colour vision
Available versions for ERULES-1963177438-11292
ED Decision 2019/002/R
found in: Aircrew (1178/2011) Part-FCL Part-MED Part-CC Part-ARA Part-ORA Part-DTO (Aug 2023)
From
Aircrew (1178/2011... (Nov 2025)
Aircrew (1178/2011... (Dec 2024)
Aircrew (1178/2011... (Aug 2023)
From section
To
Aircrew (1178/2011... (Nov 2025)
Aircrew (1178/2011... (Dec 2024)
Aircrew (1178/2011... (Aug 2023)
To section
No visible text changes
0 removals
0 additions
View
Rich
Plain
Sync scrolling
Share
From
Show details
Hide details
To
Show details
Hide details
Version
Show side by side
AMC1 MED.B.075 Colour vision ED Decision 2019/002/R (a)At revalidation and renewal examinations, colour vision should be tested on clinical indication. (b)The Ishihara test (24 plate version) is considered passed if the first 15 plates, presented in a random order, are identified without error. (c) Those failing the Ishihara test should be examined either by: (1) anomaloscopy (Nagel or equivalent). This test is considered passed if the colour match is trichromatic and the matching range is 4 scale units or less, or if the anomalous quotient is acceptable; or by (2) lantern testing with a Spectrolux, Beynes or Holmes-Wright lantern. This test is considered passed if the applicant passes without error a test with accepted lanterns. (3) Colour Assessment and Diagnosis (CAD) test. This test is considered passed if the threshold is less than 6 standard normal (SN) units for deutan deficiency, or less than 12 SN units for protan deficiency. A threshold greater than 2 SN units for tritan deficiency indicates an acquired cause which should be investigated.
AMC1 MED.B.075 Colour vision ED Decision 2019/002/R (a)At revalidation and renewal examinations, colour vision should be tested on clinical indication. (b)The Ishihara test (24 plate version) is considered passed if the first 15 plates, presented in a random order, are identified without error. (c) Those failing the Ishihara test should be examined either by: (1) anomaloscopy (Nagel or equivalent). This test is considered passed if the colour match is trichromatic and the matching range is 4 scale units or less, or if the anomalous quotient is acceptable; or by (2) lantern testing with a Spectrolux, Beynes or Holmes-Wright lantern. This test is considered passed if the applicant passes without error a test with accepted lanterns. (3) Colour Assessment and Diagnosis (CAD) test. This test is considered passed if the threshold is less than 6 standard normal (SN) units for deutan deficiency, or less than 12 SN units for protan deficiency. A threshold greater than 2 SN units for tritan deficiency indicates an acquired cause which should be investigated.
##### AMC1 MED.B.075 Colour vision *ED Decision 2019/002/R* (a)At revalidation and renewal examinations, colour vision should be tested on clinical indication. (b)The Ishihara test (24 plate version) is considered passed if the first 15 plates, presented in a random order, are identified without error. (c) Those failing the Ishihara test should be examined either by: (1) anomaloscopy (Nagel or equivalent). This test is considered passed if the colour match is trichromatic and the matching range is 4 scale units or less, or if the anomalous quotient is acceptable; or by (2) lantern testing with a Spectrolux, Beynes or Holmes-Wright lantern. This test is considered passed if the applicant passes without error a test with accepted lanterns. (3) Colour Assessment and Diagnosis (CAD) test. This test is considered passed if the threshold is less than 6 standard normal (SN) units for deutan deficiency, or less than 12 SN units for protan deficiency. A threshold greater than 2 SN units for tritan deficiency indicates an acquired cause which should be investigated.