Light
Dark
System
Log In
Loading...
Compare / EASA/
Incorporated Amendments
/
Compare & Highlight Differences
ORA.FSTD.105 Maintaining the FSTD qualification
Available versions for ERULES-1963177438-11036
Regulation (EU) 2024/2076
found in: Aircrew (1178/2011) Part-FCL Part-MED Part-CC Part-ARA Part-ORA Part-DTO (Dec 2024)
Regulation (EU) No 290/2012
found in: Aircrew (1178/2011) Part-FCL Part-MED Part-CC Part-ARA Part-ORA Part-DTO (Aug 2023)
Regulation (EU) 2026/781
found in: Easy Access Rules for Aircrew (Oct 2026)
From
Easy Access Rules ... (Oct 2026)
Aircrew (1178/2011... (Nov 2025)
Aircrew (1178/2011... (Dec 2024)
Aircrew (1178/2011... (Aug 2023)
From section
To
Easy Access Rules ... (Oct 2026)
Aircrew (1178/2011... (Nov 2025)
Aircrew (1178/2011... (Dec 2024)
Aircrew (1178/2011... (Aug 2023)
To section
No visible text changes
0 removals
0 additions
View
Rich
Plain
Sync scrolling
Share
From
Show details
Hide details
To
Show details
Hide details
Version
Show side by side
ORA.FSTD.105 Maintaining the FSTD qualification Regulation (EU) No 290/2012 (a) In order to maintain the qualification of the FSTD, an FSTD qualification certificate holder shall run the complete set of tests contained within the master qualification test guide (MQTG) and functions and subjective tests progressively over a 12-month period. (b) The results shall be dated, marked as analysed and evaluated, and retained in accordance with [ORA.FSTD.240](#_DxCrossRefBm894736344), in order to demonstrate that the FSTD standards are being maintained. (c) A configuration control system shall be established to ensure the continued integrity of the hardware and software of the qualified FSTD.
ORA.FSTD.105 Maintaining the FSTD qualification Regulation (EU) No 290/2012 (a) In order to maintain the qualification of the FSTD, an FSTD qualification certificate holder shall run the complete set of tests contained within the master qualification test guide (MQTG) and functions and subjective tests progressively over a 12-month period. (b) The results shall be dated, marked as analysed and evaluated, and retained in accordance with [ORA.FSTD.240](#_DxCrossRefBm1199964196), in order to demonstrate that the FSTD standards are being maintained. (c) A configuration control system shall be established to ensure the continued integrity of the hardware and software of the qualified FSTD.
#### ORA.FSTD.105 Maintaining the FSTD qualification *Regulation (EU) No 290/2012* (a) In order to maintain the qualification of the FSTD, an FSTD qualification certificate holder shall run the complete set of tests contained within the master qualification test guide (MQTG) and functions and subjective tests progressively over a 12-month period. (b) The results shall be dated, marked as analysed and evaluated, and retained in accordance with [ORA.FSTD.240](#_DxCrossRefBm1743304020), in order to demonstrate that the FSTD standards are being maintained. (c) A configuration control system shall be established to ensure the continued integrity of the hardware and software of the qualified FSTD.
#### ORA.FSTD.105 Maintaining the FSTD qualification *Regulation (EU) 2026/781* (a) In order to maintain the qualification of the FSTD, an FSTD qualification certificate holder shall run the complete set of tests contained within the master qualification test guide (MQTG) and functions and subjective tests progressively over a 12-month period. (b) The results shall be dated, marked as analysed and evaluated, and retained in accordance with [ORA.FSTD.240](#_DxCrossRefBm2072463115), in order to demonstrate that the FSTD standards are being maintained. (c) A configuration control system shall be established to ensure the continued integrity of the hardware and software of the qualified FSTD. *[applicable until 29 April 2028 — Regulation (EU) No 290/2012]* (a) The organisation operating the FSTD shall perform all of the following to maintain the FSTD qualification: (1) maintain the FSTD in a condition in which it consistently performs in accordance with the qualification basis, including by conducting functional pre-flight checks within the 24 hours preceding the use of the FSTD for training, testing or checking; (2) conduct the complete set of objective tests contained in the MQTG progressively over a 12-month cycle. Results from those tests shall be evaluated, dated, marked as analysed and retained in accordance with point [ORA.FSTD.240](#_DxCrossRefBm2072463115) in order to demonstrate that compliance with the FSTD qualification basis is being maintained; (3) conduct the complete set of functions and subjective tests contained in the MQTG progressively over a 24-month cycle. The results of each fly-out shall meet all the following requirements: (i) be accompanied by a declaration that the FSTD has been tested; (ii) demonstrate that the compliance with the FSTD qualification basis is being maintained; (iii) be retained in accordance with point ORA.FSTD.240; (4) preserve the integrity of the hardware and software of the FSTD and establish and maintain a configuration control system, including database management. (b) If non-compliance is identified during the tests referred to in points (a)(2) and (3), the organisation shall implement corrective actions to address the non-compliance. The evidence of the implemented corrective actions shall be retained in accordance with point ORA.FSTD.240. (c) If an organisation plans to remove an FSTD from active status for a prolonged period, the organisation shall take the following steps: (1) notify the competent authority; (2) establish suitable controls for the period during which the FSTD is inactive. The organisation shall agree with the competent authority a plan for the deactivation, storage and reactivation to ensure that the FSTD can be restored to active status at its original qualification. *[applicable from 30 April 2028 — Regulation (EU) 2026/781]*
Contact support