CS 25.854 Lavatory fire protection
Available versions for ERULES-1963177438-10199
ED Decision 2017/015/R
found in: CS-25 Amdt 27 - Large Aeroplanes (Jan 2023)
Version
CS-25 Amdt 27 - La... (Jan 2023)
Section
Share
Version
Show details
Hide details
Version
CS 25.854 Lavatory fire protection ED Decision 2017/015/R (See AMC 25.854) For aeroplanes with a passenger capacity of 20 or more, or with a cabin length of 18.29 m (60 ft) or more: (a) Each lavatory must be equipped with a smoke detector system or equivalent that provides a warning light in the cockpit, or provides a warning light or audible warning in the passenger cabin that would be readily detected by a cabin crew member; and (b) Each lavatory must be equipped with a built-in fire extinguisher for each disposal receptacle for towels, paper, or waste, located within the lavatory. The extinguisher must be designed to discharge automatically into each disposal receptacle upon occurrence of a fire in that receptacle. [Amdt 25/19]