Light
Dark
System
Log In
Loading...
Compare / EASA/
Incorporated Amendments
/
Compare & Highlight Differences
CS 25.1360 Precautions against injury
Available versions for ERULES-1963177438-10164
ED Decision 2016/010/R
found in: CS-25 Amdt 27 - Large Aeroplanes (Jan 2023)
Version
CS-25 Amdt 27 - La... (Jan 2023)
Section
Share
Version
Show details
Hide details
Version
CS 25.1360 Precautions against injury ED Decision 2016/010/R (See AMC 25.1360) (a) *Shock*. The electrical system must be designed so as to minimise the risk of electric shock to crew, passengers and servicing personnel and also to maintenance personnel using normal precautions. (See [AMC 25.1360(a)](#_DxCrossRefBm1709821673) and [CS 25.899](#_DxCrossRefBm1709821056).) (b) *Burns*. The temperature of any part, which has to be handled during normal operation by the flight crew, must not be such as to cause dangerous inadvertent movement, or injury to the crewmember. (See [AMC 25.1360(b)](#_DxCrossRefBm1709821672).) [Amdt 25/18]