Navigate / EASA

ETSO-C64b

ED Decision 2016/029/R

Oxygen Mask Assembly, Continuous Flow, Passenger

1 Applicability

This ETSO gives the requirements which new models of oxygen mask, continuous flow, passenger, that is designed and manufactured on or after the date of this ETSO must meet in order to be identified with the applicable ETSO marking.

2 Procedures

2.1 General

Applicable procedures are detailed in CS-ETSO Subpart A.

2.2 Specific

None.

3 Technical Conditions

3.1 Minimum Performance Standard

Standards set forth in the Society of Automotive Engineers (SAE), Inc, Document Aerospace Standard (AS) no AS 8025A, 'Passenger Oxygen Mask' dated (revised) January 1999, as modified in Appendix 1 of this ETSO.

3.2 Specific

None.

4 Marking

4.1 General

Marking is detailed in CS-ETSO Subpart A paragraph 1.2.

4.2 Specific

The markings for each mask must, in addition to the requirements in CS-ETSO Subpart A, be marked with the words 'Oxygen mask' and performance classification number as specified in SAE AS 8025 Paragraph 1.3. Additionally, the elastomer cure date (AS 8025A, paragraph 3.3.4), as well as a picture in accordance with AS8025A, paragraph 5.11, have to be marked on the article.

5 Availability of Referenced Document

See CS-ETSO Subpart A paragraph 3.

[Amdt ETSO/12]